Multiprocessing computer system for sensory evoked potentials and EEG spectral analysis for clinical neurophysiology laboratory

  • Articles
  • Published:
Journal of Medical Systems Aims and scope Submit manuscript

Abstract

A general-purpose minicomputer has been adapted and interfaced for the averaging and analysis of clinical evoked potentials and for compressed spectral arrays (CSA) of the routine EEG. In the first 2 years of operation, over 1,000 routine clinical studies of visual evoked potentials (VEP) and brainstem auditory evoked potentials (BAEP) have been performed with it, as well as over 100 CSAs and a variety of special and research studies. The CSA modality gives comparative frequency-domain pictures of left and right hemisphere power. An attached graphics terminal gives a live cumulative display of the EP and CSA. In addition, the system has automated and comprehensive physician-interactive graphics analysis and report generation capabilities. The reports are finalized versions used in the patient's chart, minimizing clerical efforts.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Streletz, L. J., Steben, J. D., and Saltzman, E., The clinical use of a minicomputer to assist the acquisition, analysis, and reporting of visual evoked potentials,Proceedings of the Fourth Annual Conference of I.E.E.E. Engineering in Medicine and Biology Society (A. R. Potvin and J. H. Potvin, eds.), 1982, pp. 56–59.

  2. Collins, D. w. K., Black, J. L., and Mastaglia, F. L., Pattern-reversal visual evoked potentials.J. Neurol. Sci. 36:83–95, 1978.

    Google Scholar 

  3. Black, J. L., Isele, D. F., Fleming, J. R., et al., A versatile averaging system for neurophysiology.Comput. Biol. Med. 6:9–21, 1976.

    Google Scholar 

  4. Brackman, D. E., Selters, W. A., and Don, M., Electric response audiometry.Otolaryngology (G. M. English, ed.), Harper & Row, Philadelphia, 1982, pp. 1–21.

    Google Scholar 

  5. Bickford, R. G., Brimm, J., Berger, L., and Aung, M., Application of compressed spectral array in clinical EEG.Automation of Clinical Electroencephalography (P. Kellaway and I. Petersen, eds.), Raven Press, New York, 1973, pp. 55–64.

    Google Scholar 

  6. Chiappa, K. H., Burke, S. R., and Young, R. R., Results of EEG monitoring during 367 carotid endarterectomies.Stroke 10:381–388, 1979.

    Google Scholar 

  7. Bourne, J. R., Ward, J., Teschan, P., Mussa, M., Johnston, H., Jr., and Ginn, H., Quantitative assessment of the EEG in renal disease.Electroencephaol. Clin. Neurophysiol. 39:377–388, 1975.

    Google Scholar 

  8. Chiappa, K. H., and Ropper, A. H., Evoked potentials in clinical medicine.N. Engl. J. Med. 306:1140–1150, 1982.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Steben, J.D., Streletz, L.J. & Fariello, R.G. Multiprocessing computer system for sensory evoked potentials and EEG spectral analysis for clinical neurophysiology laboratory. J Med Syst 9, 347–363 (1985). https://doi.org/10.1007/BF00992573

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00992573

Keywords

Navigation