Abstract
A novel approach to the on-line mass determination of peptides from digested proteins by scanning infrared matrix-assisted laser desorption/ionization (scanning-IR-MALDI) is described. The peptides were continuously collected directly onto a PVDF (polyvinylidene fluoride) strip during a HPLC run. Individual peptides were detected by lining up the PVDF strip with the UV trace from the HPLC run, using visible dye markers as reference points. The local resolution of the peptides on the PVDF membrane is preserved during matrix incubation for MALDI-MS as shown by comparing the UV chromatogram and the total ion current (TIC) from an on-line coupled electrospray ionization (ESI) mass spectrometer with the scanning-IR-MALDI data from the corresponding areas on the PVDF strip. The intensities of the mass profiles obtained by scanning-IR-MALDI reflect the amount of peptides present on the PVDF strip. The higher sensitivity of IR-MALDI-MS yielded mass information not detectable by ESI-MS. After the scanning-IR-MALDI experiment, the same membrane strip can be used directly for automated Edman degradation. Comparable initial and repetitive yields were obtained for blotted peptides with and without matrix incubation.
Similar content being viewed by others
REFERENCES
Blais, J. C., Nagnan-Le-Meillour, P., Bolbach, G., and Tabet, J. C. (1996). Rapid Commun. Mass Spectrom. 10, 1–4.
Covey, T. R., Bronner, R. F., Shushan, B. I., and Henion, J. (1988). Rapid Commun. Mass Spectrom. 2, 249–256.
Eckerskorn, C., and Grimm, R. (1996). Electrophoresis 17, 899–906.
Eckerskorn, C., Strupat, K., Karas, M., Hillenkamp, F., and Lottspeich, F. (1992). Electrophoresis 13, 664–665.
Hsi, K.-L., Kochersperger, M. L., Werner, W. E., Grimley, C., Ly, H., Sandell, S., and Yuan, P. M. (1995). In PE Applied Biosystems: “Moving Forward in Protein Analysis” 1995, Posterior Presentations, pp. 1–10.
Mehl, E., Plambeck, J., and Lottspeich, F. (1993). In Würzburger Kolloquium 1993 (Engelhardt, H., ed.), Bertsch, Straubing, pp. 189–195.
Schreiner, M., Strupat, K., Lottspeich, F., and Eckerskorn, C. (1996). Electrophoresis 17, 954–961.
Strupat, K., Eckerskorn, C., Karas, M., and Hillenkamp, F. (1994a). In Proceedings of the 42nd ASMS Conference on Mass Spectrometry and Allied Topics.
Strupat, K., Karas, M., Hillenkamp, F., Eckerskorn, C., and Lottspeich, F. (1994b). Anal. Chem. 66, 464–470.
Vestling, M., and Fenselau, C. (1994). Anal. Chem. 64, 471–476.
Zhang, H., and Caprioli, R. M. (1996a). In Proceedings of the 44nd ASMS Conference on Mass Spectrometry and Allied Topics, THP237.
Zhang, H., and Caprioli, R. M. (1996b). J. Mass Spectrom. 31, 690–692.