Abstract
Pulmonary impedance, ZL, measured from 2 to 32 Hz in anesthetized, intubated and paralyzed bonnet monkeys (Macaca radiata) was fitted to a variety of linearlumped parameter mechanical networks. Parameter values for each network were obtained by minimizing the average of the percent distance, Dr, between the computed network impedance and measured ZL at all frequencies. Measured resistance, RL, decreased from 2 to 8 Hz and increased from 8 to 32 Hz indicating that a single series resistance-inertance-compliance (RIC) network was not optimal (Dr∼19%). Networks consisting of two series RIC pathways in parallel resulted in a lower Dr (∼14%), but parameter values were difficult to interpret. Despite not modeling the decrease in RL with frequency below 8 Hz, an airway wall compliance, C aw , network in which the airways were separated into central and peripheral components resulted in an even lower Dr (∼11%). In addition, parameter values were easy to interpret, consistent among our “normal” monkeys and changed consistently and explainably with change in lung mechanics induced by decrease in lung volume. We conclude that (1) networks containing both parallel pathways and C aw are necessary to model ZL over the entire frequency range (2–32 Hz), (2) the effect of C aw is an important determinant of ZL above 8 Hz, and (3) a six-parameter C aw network with the ratio of C aw to parenchymal compliance, Cp, fixed may prove useful in interpreting changes in ZL induced by alterations in lung mechanics in monkeys.
Similar content being viewed by others
References
Bobbaers, H., J. Clement and K.P. van de Woestijne. Dynamic viscoelastic properties of the canine trachea.J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 44:137–143, 1978.
Crandall, I.B.Theory of Vibrating Systems and Sound. New York: Van Nostrand, 1926, pp. 229–241.
Dekker, E. Transition between laminar and turbulent flow in human trachea.J. Appl. Physiol. 16:1060–1064, 1961.
Eyles, J.G. and R.L. Pimmel.IEEE Trans. Biomed. Eng. 28:313–317, 1981.
Finucane, K.E., S.V. Dawson, P.D. Phelan and J. Mead. Resistance of intrathoracic airways of healthy subjects during periodic flow.J. Appl. Physiol. 38:517–530, 1975.
Grimby, G., T. Takishima, W. Graham, P. Macklem and J. Mead. Frequency dependence of flow resistance in patients with obstructive lung disease.J. Clin. Invest. 47:1455–1465, 1968.
Hoppin, F.G., Jr., M. Green and M.S. Morgan. Relationship of central and peripheral airway resistance to lung volume in dogs.J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 44:728–737, 1978.
Jackson, A.C. and J.W. Watson. Oscillatory mechanics of the respiratory system in normal rats.Respir. Physiol. 48:309–322, 1982.
Kjeldgaard, J.M., R.W. Hyde, D.M. Speers and W.W. Reichert. Frequency dependence of total respiratory resistance in early airway disease.Am. Rev. Respir, Dis. 114:501–508, 1976.
Mead, J. Contribution of compliance of airways to frequency-dependent behavior of lungs.J. Appl. Physiol. 26:670–673, 1969.
Nagels, J., F.J. Landser, L. Van der Linden, J. Clement and K.P. van de Woestijne. Mechanical properties of lungs and chest wall during spontaneous breathing.J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 49:408–416, 1980.
Olson, D.E., G.D. Dart and F.G. Filley. Pressure drop and fluid flow regime of air inspired into the human lung.J. Appl. Physiol. 28:482–494, 1970.
Olson, D.E., M.F. Sudlow, K. Horsfield and F.G. Filley. The convective patterns of flow during inspiration in the upper and central airways.Arch. Int. Med. 131:51–58, 1973.
Otis, A.B., C.B. McKerrow, R.A. Bartlett, J. Mead, M.B. McIlroy, N.J. Selverstone and E.P. Radford, Jr. Mechanical factors in distribution of pulmonary ventilation.J. Appl. Physiol. 8:427–444, 1956.
Pedley, T.J., R.C. Schroter and M.F. Sudlow. Gas flow and mixing in the airways. In:Bioengineering Aspects of the Lung, edited by J. West. New York: Dekker, 1977.
Slutsky, A.S., G.G. Berdine and J.M. Drazen. Steady flow in a model of human central airways.J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 49:417–423, 1980.
Slutsky, A.S., G.G. Berdine and J.M. Drazen. Oscillatory flow and quasi-steady behavior in model of human central airways.J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 50:1293–1299, 1981.
Thurston, G.B. Periodic flow through circular tubes.J. Acoust. Soc. Am. 24:653–656, 1952.
Tsai, M.J., R.L. Pimmel, E.J. Stiff, P.A. Bromberg and R.L. Hamlin. Respiratory parameter estimation using forced oscillatory impedance data.J. Appl. Physiol.: Respirat. Environ. Exercise Physiol. 43:322–330, 1977.
Wegner, C.D., A.C. Jackson, J.D. Berry and J.R. Gillespie. Dynamic respiratory mechanics in monkeys measured by forced oscillations.Respir. Physiol. 55: 47–61, 1984.
Woolcock, A.J., N.J. Vincent and P.T. Macklem. Frequency dependence of compliance as a test for obstruction in the small airways.J. Clin. Invest. 48:1097–1106, 1969.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wegner, C.D., Jackson, A.C. & Gillespie, J.R. Linear-lumped-parameter modeling of pulmonary impedance in monkeys. Ann Biomed Eng 14, 401–415 (1986). https://doi.org/10.1007/BF02367361
Issue Date:
DOI: https://doi.org/10.1007/BF02367361