Abstract
Detailed kinetic studies of ion channel gating are best carried out using the patch-clamp technique which permits the measurement of the ionic current through individual channels. Typical patch-clamp recordings show the current signal, in the form of a sequence of rectangular pulses (analogous to a random telegraph signal), riding on slow baseline drift, partially obscured by high-frequency noise and distorted by filtering. In order to analyze such recordings, we have developed a set of interactive Pascal programs based on a feature-detection algorithm capable of identifying current transitions in multiple-channel recordings in the presence of substantial levels of noise and drift. Software operation is largely automated but includes provisions for examination and correction of the output. The software was optimized and systematically evaluated using simulated data with variable amounts of noise and drift. Results indicate that satisfactory performance is obtained for signal-to-noise ratio as low as four even with uncommonly large baseline drift. Steady-state processing speeds varied from 1000 to 4000 samples per second depending on data complexity.
Similar content being viewed by others
References
Colquhoun D, Singworth FJ (1983) Fitting and statistical analysis of single-channel records. In: Sakmann B, Neher E (eds) Single channel recording. Plenum Press, New York, pp 191–263
Cottrell GA, Duff DA, Lambert JJ (1983) An inexpensive microcomputer system for analysis of single channel currents. J Neurosci Methods 9:259–267
Cox JR, Nolle FM, Fozzard HA, Oliver GC Jr (1968) AZTEC: a preprocessing program for real-time ECG rythm analysis. IEEE Trans Biomed Eng BME-15:128–129
Fitzhugh R (1983) Statistical properties of the asymmetric random telegraph signal with applications to single-channel analysis. Math Biosci 64:75–89
Hamill OP, Marty A, Neher E, Sakmann B, Singworth FJ (1981) Improved patch-clamp techniques for high resolution current recording from cells and cell-free membrane-patches. Pflügers Arch 391:85–100
Hamming RW (1983) Digital Filters, 2nd edn, Prentice-Hall, Englewood Cliffs, NJ, 255 pp
Hille B (1984) Ionic channels of excitable membranes, Sinauer Associates, Sunderland, MA, 426 pp
Jackson MB (1985) Stochastic behavior of a many-channel system. Biophys J 47:129–137
Kegel DR, Wolf BD, Sheridan RE, Lester HA (1985) Software for electrophysiological experiments with a personal computer. J Neurosci Methods 12:317–330
Kernighan BW, Plauger PD (1981) Software tools in Pascal. Addison-Wesley, Reading, Mass, 366 pp
Knuth DE (1969) The art of computer programming, vol 2, Seminumerical algorithms. Addison-Wesley, Reading, Mass, 534 pp
Papoulis A (1965) Probability, random variables and stochastic processes. McGraw-Hill, New York, 583 pp
Roux B, Sauve R (1985) A general solution to the time interval omission problem applied to single channel analysis. Biophys J 48:149–158
Sachs F (1983) Automated analysis of single-channel records. In: Sakmann B, Neher E (eds) Single channel recording. Plenum Press, New York, pp 265–285
Sachs F, Neil J, Barkakati N (1982) The automated analysis of data from single ionic channels. Pflügers Arch 395:331–340
Sigworth FJ (1983) An example of analysis. In: Sakmann B, Neher E (eds) Single channel recording. Plenum Press, New York, pp 301–321
Singer JJ, Walsh JV Jr (1984) Large conductance Ca2+-activated K+ channels in smooth muscle cell membrane: reduction in unitary currents due to internal Na+ ions. Biophys J 45:68–70
Singer JJ, Walsh JV Jr (1986) Large conductance Ca2+-activated K+ channel in freshly dissociated smooth muscle cells. Membr Biochem 6:83–110
Walsh JV Jr, Singer JJ (1983) Ca2+-activated K+ channels in vertebrate smooth muscle cells. Cell Calcium 4:321–330
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Vivaudou, M.B., Singer, J.J. & Walsh, J.V. An automated technique for analysis of current transitions in multilevel single-channel recordings. Pflugers Arch. 407, 355–364 (1986). https://doi.org/10.1007/BF00652618
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00652618