Skip to main content
Log in

Heat transfer and pressure drop of a transversely finned concentric annulus with longitudinal flow

Wärmeübergang und Druckverlust in einem querberippten konzentrischen Ringkanal bei Längsströmung

  • Published:
Wärme - und Stoffübertragung Aims and scope Submit manuscript

Abstract

The characteristics of heat transfer and pressure drop have been experimentally studied for the fully developed concentric annular flow with transverse fins normal to the flow direction by the naphthalene sublimation technique. Correlations for calculating the heat transfer coefficient with different inner diametersD 0 of the outer tube are presented. A “characteristic Reynolds number” has been proposed, by which the predominant role of the transverse fins can be evaluated. It has been indicated that the inner diameterD 0 has much more effect on pressure drop than on heat transfer. The effect ofD 0 on the overall performance is also compared under the same flow velocity or flow rate. It has been found that the effect of developing flow on heat transfer is significant and should be taken into account during experiment.

Zusammenfassung

Mit Hilfe der Naphthalin-Sublimationstechnik werden die Wärmeübergangs- und Druckverlustcharakteristiken in quer zur voll ausgebildeten Strömung bei berippten Ringkanälen experimentell ermittelt und Korrelationen zur Berechnung des Wärmeübergangskoeffizienten bei variablen InnendurchmesserD 0 des umschließenden Rohres angegeben. Ferner wird eine charakteristische Reynolds-Zahl vorgeschlagen, über die sich der dominierende Einfluß der Querrippen erfassen läßt. Es zeigte sich, daß der InnendurchmesserD 0 den Druckverlust wesentlich mehr beeinflußt als den Wärmeübergang. Auch wurde die Abhängigkeit des Gesamt-Übertragungsverhaltens vonD 0 bei gleicher Strömungsgeschwindigkeit bzw. Volumenstromdichte ermittelt. Es zeigte sich, daß die Ausbildung des Strömungsprofils bei Einlaufströmung den Wärmeübergang signifikant beeinflußt und deshalb im Experiment zu berücksichtigen ist.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Obermeier, E.; Schaber, A.: Experimental investigation of heat transfer from transverse finned tubes with longitudinal flow. Proc. of 6th Int. Heat Transfer Conf., Toronto (1978) 613–617

  2. Kameoka, T.; Nakamura, K.: Investigation on convective heat transfer from transverse plate finned surface. Bull. JSME. 18 (1975) 33–40

    Google Scholar 

  3. Knudsen, J. G.; Katz, D. L.: Heat transfer and pressure drop in annuli. Chem. Engng. Progr. 46 (1950) 490–500

    Google Scholar 

  4. Ueda, T.; Hanada, I.: Experiment of heat transfer on the surface with transverse fins for flow direction. Bull. JSME. 7 (1964) 759–768

    Google Scholar 

  5. Eckert, E. R. G.; Goldstein, R. J.: Measurements in Heat Transfer. 2nd ed. New York: McGraw-Hill (1976)

    Google Scholar 

  6. VDI-GVC: VDI-Wärmeatlas, Berechnungsblätter für den Wärmeübergang. Verlag des Vereins Deutscher Ingenieure. Düsseldorf (1977)

  7. Incropera, F. P.; Dewitt, D. P.: Introduction to Heat Transfer. New York: Wiley (1985)

    Google Scholar 

  8. Rosenow, W. M.; Hartnett, J. P.: Handbook of Heat Transfer. New York: McGraw-Hill (1975)

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jin, Y., Ling, C., Chen, Z. et al. Heat transfer and pressure drop of a transversely finned concentric annulus with longitudinal flow. Wärme- und Stoffübertragung 28, 243–249 (1993). https://doi.org/10.1007/BF01539489

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01539489

Keywords

Navigation