Skip to main content
Log in

PET tomography in studies of distributions of 7.6-min potassium 38 in the dog heart

  • Published:
European Journal of Nuclear Medicine Aims and scope Submit manuscript

Abstract

Potassium 38 emits a 2.68-MeV (max) positron, followed promptly by a 2.17-MeV γ-ray in 99.8% of its disintegrations. A positron is emitted also, followed by a 3.94-MeV γ-ray, in 0.2% of the decays. The pairs of 511-keV PET±γ-quanta, which are emitted at 180±0.3° to each other, are in true coincidence with the prompt γ-rays emitted by the daughter nucleus, within the resolving time of PET instrumentation. Studies made with phantoms by means of a commercial version of the MGH PET camera demonstrated that quantitatively satisfactory images are derived, despite the presence of the prompt γ-rays. Two-dimensional (2-D) focal-plane images reveal high uptake of38K promptly in the myocardium of dogs, under barbiturate sedation. Third-dimensional (3-D) transverse section PET tomographic images, through four 1.0-cm-thick heart “slices” orthogonal to the plane of the 2-D images and with 1.4-cm sequential spacing, show38K uptake to be concentrated especially highly in the left ventricle, as expected. Peak levels of activity were observed over the myocardium at 12 s after intravenous bolus injection of ionic38K. Dynamic mode 2-D images were taken at intervals as short as 0.5 s and extending to 1 h.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Brownell GL, Correia JA, Zamenhof RG (1978) Positron instrumentation. In: Lawrence JH, Budinger TF (eds) Recent advances in nuclear medicine, vol 5, Grune & Stratton, New York, 1–49

    Google Scholar 

  • Brownell GL, Sweet WH (1953) Localization of brain tumors with positron emitters. Nucleonics 11 (11):40–45

    Google Scholar 

  • Budinger TF, Derenzo SE, Gullberg GT, Greenberg WL, Huesman RH (1977) Emission computer assisted tomography with singlephoton and positron annihilation photon emitters. J Comput Assist Tomogr 1:131–145

    Google Scholar 

  • Carroll LR (1978) Design and performance characteristics of a production model positron imaging system. IEEE Trans Nucl Sci NS-25:606–614

    Google Scholar 

  • DeBenedetti S, Cowan CE, Konneker WR, Primakoff H (1950) On the angular distribution of two-photon annihilation radiation. Phys Rev 77:205–212

    Google Scholar 

  • Hamlin RL (1960) Radiographic anatomy of heart and great vessels in healthy living dogs. J Am Vet Med Assoc 136:265–273

    Google Scholar 

  • Hevesy GC (1951) The application of radioactive indicators in biochemistry. J Chem Soc 1618–1639

  • Hofstadter R (1948) Alkali halide scintillation counters. Phys Rev 74:100–101, 628(E)

    Google Scholar 

  • Joliot F, Curie I (1934) Artificial production of a new kind of radio-element. Nature (London) 133:201–202

    Google Scholar 

  • Lambrecht RM, Hara T, Gallagher BM, Wolf AP, Ansari A, Atkins H (1978) Production of potassium-38 for myocardial perfusion studies. Int J Applied Radiation Isotopes 29:667–671

    Google Scholar 

  • Lederer CM, Shirley VS (eds) (1978) Table of isotopes, 7th edn. Wiley, New York

    Google Scholar 

  • Myers WG (1973) Radiopotassium-38 for in vivo studies of dynamic processes. J Nucl Med 14:359–360

    Google Scholar 

  • Myers WG, Bigler RE, Graham MC (1979) Studies on the distribution of potassium-38 in vivo by means of positron-electron transmutation (PET) tomography. Int J Radiat Oncol Biol Phys 5:Suppl 2, 72

    Google Scholar 

  • Myers WG (1980) PET = Positron + Electron Transmutation. J Nucl Med 21:1200 (Letter to the Editor)

    Google Scholar 

  • Myers WG, Benua RS, Yeh SDJ, Bigler RE, Graham MC, Dahl JR, Lee R, Reiman RE, Bading JR, Laughlin JS (1981) Kinetics of potassium-38 in the heart intercompared by means of a positron-electron transmutation (PET) tomograph and a rectilinear high-energy gamma (HEG) scanner. In: Medical radionuclide imaging, vol II, IAEA, Vienna, 281–290

    Google Scholar 

  • Phelps ME (1977) Emission computed tomography. Sem Nucl Med 7:337–365

    Google Scholar 

  • Poe ND (1972) Comparative myocardial uptake and clearance characteristics of potassium and cesium. J Nucl Med 13:557–560

    Google Scholar 

  • Tilbury RS, Myers WG, Chandra R, Dahl JR, Lee R (1980) Production of 7.6-min potassium-38 for medical use. J Nucl Med 21:867–871

    Google Scholar 

  • Wrenn FR Jr, Good ML, Handler P (1951) The use of positron emitting radioisotopes for the localization of brain tumors. Science 113:525–527

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Myers, W.G., Bigler, R.E. & Graham, M.C. PET tomography in studies of distributions of 7.6-min potassium 38 in the dog heart. Eur J Nucl Med 9, 272–277 (1984). https://doi.org/10.1007/BF00803249

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00803249

Keywords

Navigation