Skip to main content
Log in

Retropatellar contact characteristics in total knee arthroplasty with and without patellar resurfacing

  • Original paper
  • Published:
International Orthopaedics Aims and scope Submit manuscript

Abstract 

Total knee replacement with and without patellar resurfacing was performed in 6 cadaver specimens. The contact pressure and contact area between femur and patella was measured at 60° of flexion. In comparison to specimens without resurfacing the specimens with small size resurfacing showed a significant decrease in contact area, whereas average and maximum pressure were unchanged. In specimens with medium size resurfacing, contact area and average pressure increased slightly, whereas maximum pressure increased significantly. Patellar resurfacing did not change the retropatellar pressure, but was associated with reduced contact area.

Résumé

 6 cadavres ont été examinés après implantation d’une prothèse totale du genou avec et sans implants de restructuration de la surface rotulienne. Les mesures de la pression et de la surface de contact ont été réalisées avec une flexion du genou à un angle de 60°. En comparant les résultats de genoux sans implants et genoux avec implants de la rotule de taille ”petite”, on remarque que ces derniers ont causé une diminution significative de la surface de contact rétro-rotulienne. Les pressions moyenne et maximum n’ont pas changé de manière déterminante. Les implants de taille ”moyenne” ont conduit à une augmentation considérable de la pression maximum et à une diminution significative de la force alors que la surface de contact et la pression moyenne ont elles, légèrement augmenté. Après la pose des deux types d’implants de la rotule on a constatée une réduction significative de la surface de contact, mais ne pas de la pression rétro-rotulienne.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Accepted: 24 January 2000

Rights and permissions

Reprints and permissions

About this article

Cite this article

Fuchs, S., Schütte, G., Witte, H. et al. Retropatellar contact characteristics in total knee arthroplasty with and without patellar resurfacing. International Orthopaedics SICOT 24, 191–193 (2000). https://doi.org/10.1007/s002640000140

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002640000140

Keywords

Navigation