Summary
The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.
Résumé
Le clou droit intra-médullaire, d'usage courant, comporte un certain nombre de limitations et d'inconvénients. A la suite d'études radiographiques et métallurgiques, nous avons mis au point un nouveau clou courbe, en feuille de trèfle à la coupe, fabriqué avec un nouvel alliage nickel-chrome-cobalt (COP). Le clou est incurvé, avec un sillon sur sa face convexe et un rayon de courbure de 115 cm, correspondant à la convexité anatomique du fémur humain. Ce clou a été utilisé de façon satisfaisante depuis 1971, car il procure non seulement une fixation interne plus stable, mais permet également la synthèse des fractures situées au-dessous du tiers moyen de la diaphyse.
Similar content being viewed by others
References
Fujimaki, A.: A biomechanical study of the fracture treatment — On the intramedullary nail of the femur. J. Orthop. Ass. 47, 321–331 (1973)
Fukushima, M.: Biomechanical study on the dynamic effect of intramedullary nailing upon the human femur. J. Orthop. Ass. 47, 215–231 (1973)
Hey-Groves, E. W.: Method and result of transplantation of bone in the repair of defects caused by injury or disease. Br. J. Surg. 5, 185–242 (1917–1918)
Küntscher, G.: Die Marknagelung von Knochenbrüchen. Arch. Klin. Chir. 200, 443–455 (1940)
Müller, M. E., Allgöwer, M., Schneider, R., Willenegger, H.: Manual der Osteosynthese-AO Technik. Berlin, Heidelberg, New York: Springer-Verlag 1979
Reynold, F. C., Key, J. A.: Fracture healing after fixation with standard plates contact splints and medullary nails. J. Bone Joint Surg. [Am.] 36, 577–587 (1954)
Stuck, W. G., Thompson, M. S.: Complication of intramedullary fixation of fractures of the femur. Arch. Surg. 63, 675–687 (1951)
Sunami, Y., Ishikawa, E.: COP, a new alloy for surgical implants. Acta Med. Okayama 31, 71–80 (1977)
Watson-Jones, R., Adams, J. C., Bonnin, J. G., Burrows, H. J., King, T., Nicoll, E. A., Palmer, L., Saal, F. V., Smith, H., Trevor, D., Vaughan-Jackson, O. G., Le Vay, A. D.: Medullary nailing of fracture after fifty years. J. Bone Joint Surg. [Br.] 32, 694–729 (1950)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Onoue, Y., Sunami, Y., Fujiwara, H. et al. Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail. International Orthopaedics 3, 203–210 (1979). https://doi.org/10.1007/BF00265713