Magnification survey and spot view mammography with a new microfocus X-ray unit: detail resolution and radiation exposure

  • Original article, Breast imaging
  • Published:
European Radiology Aims and scope Submit manuscript

    We’re sorry, something doesn't seem to be working properly.

    Please try refreshing the page. If that doesn't work, please contact support so we can address the problem.

Abstract.

The aim of our study was to evaluate a mammography unit capable of magnification of up to fourfold at an equivalent or lower dose than with current systems. A prototype mammography tube with an electron-beam-focusing technology resulting in a focal spot size of 40–120 μm was combined with a highly intensifying screen-film system. To evaluate contrast-detail resolution, phantom radiographs were performed with the prototype magnification mammography system using a magnification factor of 1.7 for survey views and a magnification factor of 4.0 for spot views. They were compared with unmagnified survey views and magnification spot views (magnification factor 1.9) of a state-of-the-art mammography system. The radiation exposure was measured and mean glandular doses were calculated. The contrast-detail resolution with both prototype (m = 1.7) and conventional (m = 1.1) survey views was equivalent while the entrance dose and the mean glandular dose were approximately 50 % lower with the prototype. For spot views, the contrast-detail resolution was substantially higher for the prototype than for conventional magnification while the dose was equivalent. Dose reduction and improved detail resolution are possible with this new technology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received 3 April 1997; Revision received 22 July 1997; Accepted 3 September 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Funke, M., Breiter, N., Hermann, KP. et al. Magnification survey and spot view mammography with a new microfocus X-ray unit: detail resolution and radiation exposure. Eur Radiol 8, 386–390 (1998). https://doi.org/10.1007/s003300050399

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300050399

Navigation