Skip to main content
Log in

Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis

  • Urogenital radiology
  • Published:
European Radiology Aims and scope Submit manuscript

Abstract.

Renal artery stenosis (RAS) is a treatable cause of hypertension and renal failure for which no ideal screening technique is currently available. We evaluated the use of dynamic gadolinium-enhanced magnetic resonance angiography (MRA) for the diagnosis of RAS. Sixty-two patients with secondary hypertension were enrolled in the study. All patients had conventional renal angiography and gadolinium enhanced MRA. The sequence used was a 3D FMP SPGR sequence with the following parameters (TR: 26 ms, TE: 6.9 ms, flip angle 40 °, field of view 36 × 36 cm, matrix 246 × 256, 1 excitation). Gadolinium 0.3 mmol/kg was administered and 60 1.5-mm-thick partitions were obtained over a duration of 3.5 min. The MRA images were then compared with conventional digital subtraction angiography (DSA) images. Conventional DSA demonstrated 138 renal arteries, whereas gadolinium-enhanced MRA demonstrated 129 (93 %). Twenty-one renal artery stenoses and four occluded arteries were seen at conventional DSA. Gadolinium-enhanced MRA had a sensitivity of 88 %, specificity of 98 %, accuracy of 96 %, positive predictive value of 92 % and negative predictive value of 97 % when compared with conventional DSA. Gadolinium-enhanced MRA is an accurate technique for identifying patients with RAS. It is less sensitive in picking up accessory renal arteries.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 17 March 1998; Revision received: 30 June 1998; Accepted: 28 August 1998

Rights and permissions

Reprints and permissions

About this article

Cite this article

Thornton, J., O'Callaghan, J., Walshe, J. et al. Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis. Eur Radiol 9, 930–934 (1999). https://doi.org/10.1007/s003300050769

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s003300050769

Navigation