Skip to main content
Log in

Measurement of the optical density of the optic nerve head II: Short-time fluctuations of the optical density of the nerve head

  • Published:
Graefe's Archive for Clinical and Experimental Ophthalmology Aims and scope Submit manuscript

Abstract

The fluctuation of pallor with increasing IOP could be due to either insufficient reliability of the method or to an unrecognized pulsating phenomenon. A better arrangement should eliminate imperfection of the method. Coupling the release with the ECG should reveal a relationship to the arterial pulse rate. Neither condition could be demonstrated as the reason for the fluctuation. The connection of the fluctuation and its possible relationship to central venous pressure is discussed. The margin of error is shown, which is 9% on average.

Zusammenfassung

Die bei höherem Intraoculardruck zu beobachtenden Schwankungen der Helligkeit der Papille könnten methodisch bedingt oder Ausdruck eines physiologischen Pulsphänomens sein. Im ersten Falle müßte eine verbesserte Versuchsanordnung sie zum Verschwinden bringen, im letzteren Falle sollten die Schwankungen sich in Zusammenhang mit dem Arterienpuls bringen lassen. Es wird die Fehlerbreite der Methode bestimmt. Diese ist rund 9% und geht im Einzelfall bis max. 15%. Weiter werden Versuche angestellt, um über kurze Zeit die Reproduzierbarkeit zu erfassen. Es zeigt sich, daß sich der Fehler durch Änderung der Versuchsanordnung nicht senken läßt und daß eine eindeutige Zuordnung zum arteriellen Puls nicht herzustellen ist. Die Möglichkeit, daß die Schwankungen Ausdruck einer Interferenz mit dem zentralvenösen Druck sind, wird diskutiert.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Goldmann H, Lotmar W (1979) Rapid detection of changes in the optic disc. Stereochronoscopy. III. Retinal venous pulse as an interfering factor. Graefes Arch Clin Exp Ophthalmol 211: 243–249 (1979)

    Google Scholar 

  • Schneider M (Rein H, Schneider M.) (1964) Physiologie des Menschen. Springer-Verlag, pp 121–123

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Robert, Y., Niesel, P. & Ehrengruber, H. Measurement of the optical density of the optic nerve head II: Short-time fluctuations of the optical density of the nerve head. Graefe's Arch Clin Exp Ophthalmol 219, 183–187 (1982). https://doi.org/10.1007/BF02156844

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02156844

Keywords

Navigation