Abstract
Four commercial kits - Oxi/Ferm (OF), API 20E (AP), Minitek (MT), Flow N/F (NF) were evaluated, without additional tests, for identification of 105 opportunistic Gram-negative non-fermentative rods. OF correctly identified 42% of strains, with 35% as part (but not first) of a spectrum of identifications (SI) and 23% incorrect identification. MT yielded 75% correct identification, with 12% SI and 13% incorrect. AP correctly identified 64% of strains, with 26% SI, 10% incorrect. NF correctly speciated 70% of strains, with 24% SI, 6% incorrect. All 4 methods show deficiencies in identification of these rare but increasingly clinically encountered organisms. Addition of new tests/modification of existing ones would render these systems more capable of identifying this organisms group.
Similar content being viewed by others
References
Appelbaum PC, Stavitz J, Bentz MS, von Kuster LC (1980) Four methods for identification of gram-negative nonfermenting rods: organisms more commonly isolated in clinical specimens. J Clin Microbiol 12:271–278
Barnishan J, Ayers LW (1979) Rapid identification of non-fermentative, gramnegative rods by the Corning N/F system. J Clin Microbiol 9:239–243
Gilardi GL (1972) Infrequently encounteredPseudomonas species causing infection in humans. Ann Intern Med 77:211–215
Gilardi GL (1976) Pseudomonas species in clinical microbiology. Mt Sinai J Med 43:710–726
Gilardi GL (1980) Identification of glucose nonfermenting gram-negative bacteria. Hospital for Joint Diseases, New York, pp 1–8
Nadler H, George H, Barr J (1979) Accuracy and reproducibility of the Oxi/Ferm system in identifying a select group of unusual gram-negative bacilli. J Clin Microbiol 9:180–185
Nord C-E, Wretlind B, Dahlbäck A (1977) Evaluation of two test kits — API and Oxi Ferm tube — for identification of oxidative-fermentative gram-negative rods. Med Microbiol Immunol 163:93–97
Oberhofer TR (1979) Comparison of the API 20E and Oxi/Ferm systems in identification of nonfermentative and oxidase-positive fermentative bacteria. J Clin Microbiol 9:220–226
Shayegani M, Lee AM, McGlynn DM (1978) Evaluation of the Oxi/Ferm tube system for identification of nonfermentative or gram-negative bacilli. J Clin Microbiol 7:533–538
Shayegani M, Maupin PS, McGlynn DM (1978) Evaluation of the API 20E system for identification of nonfermentative gram-negative bacteria. J Clin Microbiol 7:539–545
Slifkin M, Pouchet GR (1977) Minitek system: identification of miscellaneous gram negative aerobic bacteria. Abstr Annu Meet Am Soc Microbiol C88, p 50
von Graevenitz A (1978) Clinical role of infrequently encountered nonfermenters. In: Gilardi GL (ed) Glucose nonfermenting gram-negative bacteria in clinical microbiology. CRC Press, Inc., West Palm Beach, Florida, pp 119–153
Warwood NM, Blazevic DJ, Hofherr L (1979) Comparison of the API 20E and Corning N/F systems for identification of nonfermentative gram-negative rods. J Clin Microbiol 10:175–179
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Appelbaum, P.C., Stavitz, J., Bentz, M.S. et al. Comparison of four methods for identification of gram-negative non-fermenters: Organisms less commonly encountered in clinical specimens. Med Microbiol Immunol 169, 163–168 (1981). https://doi.org/10.1007/BF02123589
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF02123589