Abstract
Sixty patients, who underwent phacoemulsification and implantation of a folded polyHema intraocular lens were assigned to two groups. Following wound closure 0.5 ml of 0.01% carbachol or balanced salt solution was instilled into the anterior chamber. Healon was used in all eyes but evacuated from the capsular bag behind the intraocular lens and the anterior chamber. Intraocular pressure was measured the day before as well as 6 and 18 hours postoperatively. At 6 hours the mean change of intraocular pressure from baseline was ±2.8 ± 5.3 mmHg in the carbachol group compared with +4.7 ± 8.0 mmHg in the BSS group (p < 0.0001). At 18 hours the mean change from baseline was ±3.0 ± 4.6 mmHg in the treatment group and +2.3 ± 8.5 in the control group (p < 0.0001). Intraocular pressure exceeding 25 mmHg at 6 hours was observed in 8 (27%) eyes of the control group but none of the treatment group. At 18 hours 4 (13%) eyes of the control group and 1 (3%) of the carbachol group still had an increase of intraocular pressure. Summarizing our results we conclude that the effect of Healon on the postoperative intraocular pressure is successfully counteracted by its aspiration from the capsular bag and the anterior chamber, especially when carbachol is used for intraoperative miosis.
Similar content being viewed by others
References
Cherfan GM, Rich WJ, Wright G. Raised intraocular pressure and other problems with sodium hyaluronate and cataract surgery. Trans Ophthalmol Soc UK 1983; 103: 277–279.
Barron BA, Busin M, Page C et al. Comparison of the effects of Viscoat and Healon on postoperative intraocular pressure. Am J Ophthalmol 1985; 100: 377–384.
Naeser K, Thim K, Hansen TE, et al. Intraocular pressure in the first days after implantation of posterior chamber lenses with the use of sodium hyaluronate (Healon®). Acta Ophthalmol 1986; 64: 330–337.
Olivius E, Thorburn W. Intraocular pressure after surgery with Healon®. Am Intraocular Implant Soc J 1985; 11: 480–482.
Hollands RH, Drance SM, Schulzer M. The effect of acetlycholine on early postoperative intraocular pressure. Am J Ophthalmol 1987; 103: 749–752.
Hollands RH, Drance SM, Schulzer M. The effect of carbachol on intraocular pressure after cataract extraction. Am J Ophthaimol 1987; 104: 225–228.
Wood TO. Effect of carbachol on postoperative intraocular pressure. J Cataract Refract Surg 1988; 14: 654–656.
Menapace R, Skorpik C, Wedrich A. Evaluation of 150 consecutive cases of polyHema posterior chamber lenses implanted in the bag using a small-incision technique. J Cataract Refract Surg 1990; 16: 567–577.
Menapace R, Skorpik C. Technique of small-incision implantation and capsular bag fixation for the flexible polyHema intraocular lens IOGEL®PC-12. In: Freyler H, Skorpik C, Grasl M, eds, Proceedings of the 3rd Congress of the Deutsche Ges. für Intraokularlinsen Implantation. Vienna, Springer, 1990: 130–138.
Rich WJ, Radtke ND, Cohan BE. Early ocular hypertension after cataract extraction. Br J Ophthaimol 1974; 58: 725–727.
Hayreh SS. Anterior ischemic optic neuropathy, IV: Occurrence after cataract surgery. Arch Ophthalmol 1980; 98: 1410–1416.
Fry, LL. Postoperative intraocular pressure rises: A comparison of Healon, Amvisic, and Viscoat. J Cataract Refract Surg 1989; 15: 415–420.
Assia EI, Apple DJ, Lim ES, Morgan RC, Tsai JC. Removal of viscoelastic materials after experimental cataract surgery in vitro. J Cataract Refract Surg 1992; 18: 3–6.
Gross JG, Meyer DR, Robin AL, Filar AA, Kelley JS. Increased intraocular pressure in the immediate postoperative period after extracapsular cataract extraction. Am J Ophthalmol 1988; 105: 466–469.
Linn DK, Zimmermann TJ, Nardin GF, et al. Effect of intracameral carbachol on intraocular pressure after cataract extraction. Am J Ophthalmol 1989; 107: 133–136.
Obstbaum SA, Galin MA. The effects of timolol on cataract extraction and intraocular pressure. Am J Ophthalmol 1979; 88: 1017–1019.
Tomoda T, Tuberville AW, Wood TO. Timolol and postoperative intraocular pressure. Am Intra-Ocular Implant Soc J 1984; 10: 180–181.
Ruiz RS, Wilson CA, Musgrove KH et al. Management of increased ocular pressure after cataract extraction. Am J Ophthaimol 1987; 103: 487–491.
Rich WJCC. Further studies on early postoperative ocular hypertension following cataract extraction. Trans Ophthalmol Soc UK 1983; 103: 277–279.
Lewen R, Insler MS. The effect of prophylactic acetazolamide on the intraocular pressure rise associated with Healon-aided intraocular lens surgery. Ann Ophthalmol 1985; 17: 315–318.
Fry LL. Comparison of postoperative intraocular pressure with Betagan, Betoptic, Timoptic, Iopidine, Diamox, Pilopine gel and Miostat. J Cataract Refract Surg 1992; 18: 14–19.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wedrich, A., Menapace, R. Effect of carbachol on intraocular pressure in small-incision cataract surgery. Doc Ophthalmol 80, 301–307 (1992). https://doi.org/10.1007/BF00154377
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00154377