Abstract
The Mullen and Foster method was prospectively applied for individualizing phenytoin dosage in 24 epileptic patients. Accuracy and reliability of the method were assessed by comparing predicted and measured values of plasma phenytoin steady-state concentration. The absolute difference between predicted and measured phenytoin levels was less than 15 percent in 22 of 35 cases (63 percent), between 15 and 25 percent in 8 of 35 cases (23 percent) and more than 25 percent in 6 of 35 cases (17 percent).
Sommario
Il metodo di Mullen e Foster è stato applicato al fine di individualizzare la posologia della fenitoina in 24 pazienti epilettici. Le caratteristiche di precisione ed affidabilità del metodo sono state valutate confrontando le concentrazioni plasmatiche previste con quelle misurate sperimentalmente. La differenza percentuale tra valori e misurati della concentrazione plasmatica di fenitoina è risultata inferiore al 15 per cento in 22 casi su 35 (63 per cento), compresa tra il 15 e il 25 per cento in 8 casi su 35 (23 per cento), superiore al 25 per cento in 6 casi su 35 (17 per cento).
Similar content being viewed by others
References
Bauer L.A., Blouin R.A.:Age and phenytoin kinetics in adult epileptics. Clin. Pharmacol. Ther., 31,301–304, 1982.
Gerber N., Wagner J.G.:Explanation of dosedependent decline of diphenylhydantoin plasma levels by fitting to the integrated form of the Michaelis-Menten equation. Res. Commun. Chem. Pathol. Pharmacol. 3,455–456,1972.
Ludden T.M., Hawkins D.W., Allen J.P., Hoffman S.F.:Optimum phenytoin dosage regimens. Lancet, 1,307–308,1976.
Ludden T.M., Allan J.P., Valutsky W.A., Vicuna A.V., Nappi J.M., Hoffmann S.F., Wallace J.E., Lalka D., McNay J.:Individualization of phenytoin dosage regimens. Clin. Pharmacol.Ther., 21,287–293, 1977.
MacGee J.:Rapid determination of diphenylhydantoin in blood plasma by gas chromatography. Anal. Chem., 42,421–422, 1970.
Messori A., Donati-Cori G., Tendi E.:Use of low cost programmable calculators in pharmacokinetics. In: Ostino G., Martini N., van der Kleijn E. (editors): Progress in clinical pharmacy IV. Amsterdam, Elsevier/North Holland Biomedical Press, pp.267–271, 1982.
Messori A., Valenza T., Zaccara G., Arnetoli G., Bartoli C., Donati-Cori G., Tendi E., Zappoli R.:A new programmable calculator procedure for individualizing phenytoin dosage. Drug. Intell. Clin. Pharm., 17,890–893, 1983.
Mullen P.W.:Optimal phenytoin therapy: a new technique for individualizing dosage. Clin.Pharmacol.Ther., 23,228–232, 1977.
Mullen P.W., Foster R.W.:Comparative evaluation of six techniques for determining the Michaelis-Menten parameters relating phenytoin dose and steady-state serum concentrations. J.Pharm.Pharmacol., 31,100–104, 1979.
Murphy J.E., Bruni J., Stewart R.B.:Clinical utility of six methods of predicting phenytoin doses and plasma concentrations. Am. J. Hosp. Pharm., 38,348–354, 1981.
Muscas G.C., Zaccara G.:Comparison of three techniques for individualizing phenytoin dosage: inappropriate data analysis.Am. J. Hosp. Pharm., 40,778–9, 1983.
Rambeck B., Boenigk H.E., Dunlop A., Mullen P.W., Wadsworth J., Richens A.:Predicting phenytoin dose — a revised nomogram. Ther. Drug Monitor., 1,325–333, 1979.
Richens A., Dunlop A.:Serum phenytoin levels in management of epilepsy. Lancet, 2, 247–248, 1975
Robinson F.C., Warner R.N., Gonzalez M.A.:Predicting individual phenytoin serum levels of patients seen in a private office practice. Neurology (Ny), 31,761–3, 1981.
Robinson F.C., Mayer P.R.:A graphic method for predicting individual phenytoin levels in an office practice. Ther. Drug Monit., 4,226–228, 1982.
Schumacher G.E.:Using pharmacokinetics in drug therapy. VI: Comparing methods for dealing with nonlinear drugs like phenytoin. Am. J. Hosp. Pharm., 37,128–132, 1980.
True B.,Bauer L.:Evaluation of methods to individualize phenytoin doses (abstract). Seventeenth Annual ASHP Meeting, Los Angeles, December 5–9, 1982.
Valenza T.,Program “Individualization of phenytoin dosage”, Users' Program Library Europe, Hewlett-Packard, Geneva, 1982.
Vozeh S., Koelz A., Martin E., Magun H., Scollo-Lavizzari G.;Follath F.:Predictability of phenytoin serum levels by nomograms and physicians. Eur. Neurol., 19,345–352,1980.
Vozeh S., Muir K.T., Sheiner L.B., Follath F.:Predicting individual phenytoin dosage.J. Pharmacok. Biopharm., 9,131–146, 1981.
Yuen G., Taylor J., Ludden T.M., Murphy M.J.:Phenytoin dosage predictions using Bayesian feedback (abstract). Drug Intell. Clin. Pharm., 16, 484, 1982.
Zaccara G., Messori A., Valenza T., Arnetoli G., Bartoli C., Donati-Cori G., Muscas G.C., Tendi E.;Zappoli R.:Comparison of four pharmacokinetic methods for individualizing phenytoin dosage. In: Poston J.W., De Clerq H., Bonal J. (editors): Progress in Clinical Pharmacy V, Cambridge, Cambridge University Press, 1983.