Summary
A new computerized apparatus was constructed to measure the resonant frequency of human ulnain vivo with high sensitivity and reproducibility. Experimental studies using aluminum bar and dried human bone revealed the importance of the ulna being positioned parallel to the radius, approximately 90 degree flexion of the elbow joint, and minimal muscle activity in order to demonstrate maximum resonant frequency of ulna. Measurement of bone resonance in monkeysin vivo and after removal of the bonein vitro showed good agreement. Product of F (maximum resonant frequency in Hz) and L (ulnar length in cm), FL, indicating the speed of propagation of sound wave through the ulna, showed a significant positive correlation with bone mineral content/bone width (BM/BW) measured by Norland-Cameron apparatus and age-bound decline in both sexes. Patients with osteomalacia and primary hyperparathyroid bone disease tended to have higher FL values than expected from BM/BW. Two-dimensional display of FL and BM/BW thus appears to be useful in distinguishing osteoporosis from osteomalacia better than the use of BM/BW alone.
Similar content being viewed by others
References
Jurist JM (1970) In vivo determination of the elastic response of bone I. Method of ulnar resonant frequency determination. Phys Med Biol 15:417–426
Jurist JM (1970) In vivo determination of the elastic response of bone II. Ulnar resonant frequency in osteoporotic, diabetic and normal subjects. Phys Med Biol 15:427–434
Jurist JM (1970) Reproducibility of ulnar resonant frequency measurement. Aerospace Med 41:875–878
Jurist JM (1971) Correspondence. Phys Med Biol 16:149–150
Jurist JM (1971) Effect of corticosteroids on ulnar resonant frequency. Surg Forum 22:468–469
Jurist JM (1973) Difficulties with measurement of ulnar resonant frequency. Phys Med Biol 18:289–291
Jurist JM, Folts AS (1977) Human ulnar bending stiffness, mineral content, geometry and strength. J Biochem 10:455–459
Cameron JR, Mazess RB, Sorenson JA (1968) Precision and accuracy of bone mineral determination by direct photon absorptiometry. Invest Radiol 3:141–150
Mather BS (1967) Correlation between strength and other properties of long bones. J Trauma 7:633–638
Orne D, Borders S, Petersen K (1977) Prediction of bending strength of long bones from measurements of bending stiffness and bone mineral content. J Biomech Engineering. 99:40–44
Young DR, Howard WH, Cann C, Steele CR (1979) Noninvasive measures of bone bending rigidity in the monkey (M. nedstrina). Calcif Tissue Int 27:109–115
Ziegert JC, Lewis JL (1979) The effect of soft tissue on measurements of vibrational bone motion by skin-mounted accelometers. J Mechanic Engineering 101:218–220
Greefield MA, Craven JD, Huddleston A, Kehrer ML, Wishko D, Stern R (1981) Measurement of the velocity of ultrasound in human cortical bone in vitro. Radiology 138:701–710
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fujita, T., Fukase, M., Yoshimoto, Y. et al. Basic and clinical evaluation of the measurement of bone resonant frequency. Calcif Tissue Int 35, 153–158 (1983). https://doi.org/10.1007/BF02405023
Issue Date:
DOI: https://doi.org/10.1007/BF02405023