Skip to main content
Log in

High Resolution Magnetic Resonance Imaging of the Calcaneus: Age-Related Changes in Trabecular Structure and Comparison with Dual X-Ray Absorptiometry Measurements

  • Published:
Calcified Tissue International Aims and scope Submit manuscript

Abstract.

A high-resolution magnetic resonance imaging (MRI) protocol, together with specialized image processing techniques, was applied to the quantitative measurement of age-related changes in calcaneal trabecular structure. The reproducibility of the technique was assessed and the annual rates of change for several trabecular structure parameters were measured. The MR-derived trabecular parameters were compared with calcaneal bone mineral density (BMD), measured by dual X-ray absorptiometry (DXA) in the same subjects. Sagittal MR images were acquired at 1.5 T in 23 healthy women (mean age: 49.3 ± 16.6 [SD]), using a three-dimensional gradient echo sequence. Image analysis procedures included internal gray-scale calibration, bone and marrow segmentation, and run-length methods. Three trabecular structure parameters, apparent bone volume (ABV/TV), intercept thickness (I.Th), and intercept separation (I.Sp) were calculated from the MR images. The short- and long-term precision errors (mean %CV) of these measured parameters were in the ranges 1–2% and 3–6%, respectively. Linear regression of the trabecular structure parameters vs. age showed significant correlation: ABV/TV (r 2= 33.7%, P < 0.0037), I.Th (r 2= 26.6%, P < 0.0118), I.Sp (r 2= 28.9%, P < 0.0081). These trends with age were also expressed as annual rates of change: ABV/TV (− 0.52%/year), I.Th (−0.33%/year), and I.Sp (0.59%/year). Linear regression analysis also showed significant correlation between the MR-derived trabecular structure parameters and calcaneal BMD values. Although a larger group of subjects is needed to better define the age-related changes in trabecular structure parameters and their relation to BMD, these preliminary results demonstrate that high-resolution MRI may potentially be useful for the quantitative assessment of trabecular structure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 11 March 1996 / Accepted: 9 July 1996

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ouyang, X., Selby, K., Lang, P. et al. High Resolution Magnetic Resonance Imaging of the Calcaneus: Age-Related Changes in Trabecular Structure and Comparison with Dual X-Ray Absorptiometry Measurements. Calcif Tissue Int 60, 139–147 (1997). https://doi.org/10.1007/s002239900204

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002239900204

Navigation