Summary
A catalytic determination of iodine using the As(III)/Ce(IV) reaction has been developed. The difference in reaction rate due to catalysis by iodide was measured spectrophotometrically at 310 nm. Optimum reaction conditions were investigated in order to obtain a greater sensitivity in the determination of iodine. The method can be satisfactorily used for samples containing iodine in the 0.4 to 10.0 ng range, with an overall error less than 6 %. The method has been used for the determination of iodine in serum, and gives results which compare favorably with a present clinical chemistry procedure.
Zusammenfassung
Eine katalytische Jodbestimmungsmethode auf der Grundlage der As(III)/Ce(IV)-Reaktion wurde ausgearbeitet. Die durch Jodkatalyse bedingte Differenz des Reaktionsausmaßes wurde spektralphotometrisch bei 310 nm gemessen. Das Optimum der Reaktionsbedingungen für eine größtmögliche Empfindlichkeit der Jodbestimmung wurde ermittelt. Das Verfahren kann für Jodmengen zwischen 0,4 und 10,0 ng mit Erfolg verwendet werden; der durchschnittliche Fehler beträgt weniger als 6%. Jodbestimmungen im Serum nach dieser Methode stimmen mit klinisch-chemisch ermittelten Werten gut überein.
Similar content being viewed by others
References
E. B. Sandell and I. M. Kolthoff, Mikrochim. Acta1, 9 (1937).
I. Iwasaki, S. Utsumi, and T. Ozuwa, Bull. Chem. Soc. Japan26, 108 (1953).
M. Dubravic, Analyst80, 295 (1955).
R. A. Barkley and T. G. Thompson, Analyt. Chemistry32, 154 (1960).
T. P. Hadjiiannou, Analyt. Chim. Acta30, 488. (1964).
A. L. Chaney, Ind. Eng. Chem., Analyt. Ed.12, 179 (1940).
S. B. Barker, M. J. Humphrey, and M. H. Soley, J. Clin. Invest.30, 55 (1951).
B. Zak, H. H. Willard, G. B. Myers, and A. J. Boyle, Analyt. Chemistry24, 135 (1952).
B. Zak and E. Baginski, Chemist-Analyst51, 39 (1962).
H. V. Malmstadt and T. P. Hadjiioannou, Analyt. Chemistry35, 2157 (1963).
V. J. Pileggi and G. Kessler, Clin. Chem.14, 339 (1968).
D. Jungst and L. Strauch, Z. klin. Chem. Klin. Biochem.7, 636 (1969).
G. R. Kingsley and R. R. Shaffert, Standard Method of Clin. Chem.2, 147 (1958).
N. W. Tietz, Fundamentals of Clinical Chemistry. Philadelphia: Saunders. 1970. p. 590.
O. P. Foss, L. V. Hankes, and D. D. Van Slyke, Clin. Chim. Acta5, 301 (1960).
L. W. Faulkner, R. P. Levey, and J. R. Lenards, Clin. Chem.7, 637 (1961).
K. R. Meyer, R. C. Dickenman, E. G. White, and B. Zak, Amer. J. Clin. Pathol.25, 1160 (1955).
A. Uettwiller, Z. klin. Chem. Klin. Biochem.6, 352 (1968).
A. L. Chaney, Analyt. Chemistry22, 939 (1950).
A. J. Freedman and D. N. Hume, Analyt. Chemistry22, 932 (1950).
A. Lein and N. Schwartz, Analyt. Chemistry23, 1507 (1951).
P. J. Ke and R. J. Thibert, Mikrochim. Acta [Wien]1972, 768.
G. Kessler and V. J. Pileggi, Advances in Automated Analysis, White Plains, N. Y.: Mediad. 1970. pp. 7.
J. A. Weybrew, G. Matrone, and H. M. Boxley, Analyt. Chemistry20, 759 (1948).
A. Ringbom, Z. analyt. Chem.115, 332 (1938).
G. H. Ayres, Analyt. Chemistry21, 652 (1949).
J. J. Coster and S. Natelson, Analyt. Chemistry21, 1005 (1949).
P. A. Rordiguez and H. L. Pardue, Analyt. Chemistry41, 1369 (1969).
L. W. O'Neal and E. S. Simms, Amer. J. Clin. Pathol.23, 493 (1953).
P. J. Ke and R. J. Thibert, Mikrochim. Acta [Wien]1973, 417.
V. Stolc, Z. analyt. Chem.183, 262 (1961).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ke, P.J., Thibert, R.J., Walton, R.J. et al. Catalytic determination of iodine in serum at nanogram levels using the As(III)/Ce(IV) reaction. Mikrochim Acta 61, 569–581 (1973). https://doi.org/10.1007/BF01218002
Received:
Issue Date:
DOI: https://doi.org/10.1007/BF01218002