Skip to main content
Log in

An intra-arterial electrode for intracranial electro-encephalogram recordings

  • Operative Technique and Related Results
  • Published:
Acta Neurochirurgica Aims and scope Submit manuscript

Summary

A new method for intracranial monitoring of brain electrical activity by means of an intra-arterial guide wire as electrode is described.

We carried out intracranial electro-encephalography (EEG) using an insulated Seeker Lite-10 guide wire 18 times in 14 patients: ten times in 6 patients with cerebral arteriovenous malformation (AVM) before embolization, and another 8 times in 8 patients with epilepsy. In all cases, a 2–5 times stronger high voltage potential EEG compared with scalp EEG could be recorded. In 3 patients with complex partial epilepsy, intra-arterial (IA) EEG was recorded under subdural strip electrode monitoring, and IAEEG at the sphenoidal portion of the middle cerebral artery was compared with subdural electrode recordings. Frequent interictal spike discharges recorded with subdural electrodes in the lesional medial temporal lobe were simultaneously visible on IAEEG recording.

This method is equivalent to that using a semi-invasive electrode, but ECoG recording can be performed at angiography. IAEEG is a method of electrode recording that has the possibility of clinical application.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bailey P, Gibbs FA (1951) Surgical treatment of psychomotor epilepsy. JAMA 145: 365–370

    Google Scholar 

  2. Engel J Jr, Henry TR, Risinger NM (1990) Presurgical evaluation for partial epilepsy; relative contributions of chronic depth-electrode recordings versus FDG-PET and scalp-sphenoidal ictal EEG. Neurology 40: 1670–1677

    PubMed  Google Scholar 

  3. Ross DA, Henry TR, Dickson LD (1993) A percutaneous epidural screw electrode for intracranial electroencephalogram recordings. Neurosurgery 33: 332–334

    PubMed  Google Scholar 

  4. Shimizu H, Suzuki I, Ohta Y, Ishijima B (1992) Mesial temporal subdural electrode as a substitute for depth electrode. Surg Neurol 38: 186–191

    PubMed  Google Scholar 

  5. Spencer SS (1989) Depth versus subdural electrode studies for unlocalized epilepsy. J Epilepsy 2: 123–127

    Google Scholar 

  6. Weinand ME, Wyler AR, Richey ET, Phillips BB, Somes G, (1992) Long-term ictal monitoring with subdural strip electrodes: prognostic factors for selecting temporal lobectomy candidates. J Neurosurg 77: 20–28

    PubMed  Google Scholar 

  7. Wieser HG (1991) Semi-invasive EEG: foramen ovale electrodes. In: Luders Het al (eds) Epilepsy surgery. Raven, New York, pp 361–370

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Nakase, H., Ohnishi, H., Touho, H. et al. An intra-arterial electrode for intracranial electro-encephalogram recordings. Acta neurochir 136, 103–105 (1995). https://doi.org/10.1007/BF01411445

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF01411445

Keywords

Navigation