Summary
A coating of silicone SE-54 on Chromosorb W has been converted to an analytically stable, immobilized stationary phase layer by cross-linking with an organic peroxide. Up to 10% by weight has been applied in this manner. Excellent high temperature qualities are exhibited, such as low bleeding and good base line stability, during typical analyses.
Poly (2,6-dimethyl-p-phenylene oxide) has also been crosslinked as a surface coating on Chromosorb W with an organic peroxide. From 3 to 4% by weight has been immobilized in this way. The resultant packing material, following high temperature conditioning, has been examined for use as an adsorbent of trace substances, similar to the applications to which such adsorbents as Tenax GC have commonly been applied, e.g. trace analysis of air. It appears to exhibit satisfactory properties for this analytical purpose.
Similar content being viewed by others
References
W. A. Aue, C. R. Hastings, J. Chromatogr.42, 319 (1969).
C. R. Hastings, W. A. Aue, J. M. Augl J. Chromatogr.53, 487 (1970).
C. R. Hastings, W. A. Aue, F. N. Larsen, J. Chromatogr.,60, 329 (1971).
C. Madani, E. M. Chambaz, M. Rigaud, J. Durand, P. Chebroux, J. Chromatogr.126, 161 (1976).
C. Madani, E. M. Chambaz, M. Rigaud, P. Chebroux J. C. Breton, F. Berthou, Chromatographia,10, 466 (1977).
L. Blomberg, J. Buijten, J. Gawdzik, T. Wännman, Chromatographia,11, 521 (1978).
V. Rehák, E. Smolková, Chromatographia,9, 219 (1976).
K. J. Denbleyker, T. R. Sweet, Chromatographia,13, 114 (1980).
L. Blomberg, T. Wännman, J. Chromatogr.168, 81 (1979).
L. Blomberg, T. Wännman, J. Chromatogr.186, 159 (1979).
K. Grob, G. Grob, K. Grob, Jr., J. Chromatogr.211, 243 (1981).
P. Sandra, G. Redant, E. Schach, M. Verzele, J. High Resolut. Chromatogr./Chromatogr. Commun.4, 411 (1981).
P. A. Peaden, B. W. Wright, M. L. Lee Chromatographia,15, 335 (1982).
L. Blomberg, J. Buijten, K. Markides, T. Wännman, J. Chromatogr.,239, 51 (1982).
B. W. Wright, D. A. Peaden, M. L. Lee, T. Stark, J. Chromatogr.,248, 17 (1982).
R. G. Sinclair, E. R. Hinnenkamp, K. A. Boni, D. A. Berry, W. Shuller, R. V. Lawrence, J. Chromatogr. Sci.,9, 126 (1971).
K. Grob, G. Grob, J. High Resolut. Chromatogr./Chromatogr. Commun.5, 13 (1982).
L. Blomberg, J. Buijten, K. Markides, T. Wännman, J. High Resolut. Chromatogr./Chromatogr. Commun.4, 578 (1981).
K. Markides, L. Blomberg, J. Buijten T. Wännman, J. Chromatogr.,254, 53 (1983).
W. Bertsch, V. Pretorius, M. Pearce, J. C. Thompson, N. G. Schnautz, J. High Resolut. Chromatogr./Chromatogr. Commun.5, 432 (1982).
Y. Masada, K. Hashimoto, T. Inoue, Y. Sumida, T. Kishi, Y. Suwa, J. High Resolut. Chromatogr./Chromatogr. Commun.,2, 400 (1979).
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Ghaoui, L., Shanfield, H. & Zlatkis, A. The preparation of analytically stable, immobilized stationary phase coatings on colums packing materials. Chromatographia 18, 11–14 (1984). https://doi.org/10.1007/BF02279455
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02279455