Summary
In order to prevent plugging during deactivation of small diameter (50 μm i.d.) capillary columns for gas and supercritical fluid chromatography, various high temperature deactivation methods were employed. Pure hexamethyldisilazane and hexamethyldisiloxane (a substitute for D4) were dynamically coated on the column, while a film (0.05 μm) of OV-101 was statically coated, before high temperature (450°C) treatment. Excellent deactivated columns were obtained, and no significant difference in column activity was observed using any of these three methods.
Similar content being viewed by others
References
P. A. Peaden, M. L. Lee, J. Chromatogr.259, 1 (1983).
R. C. Kong, S. M. Fields, W. P. Jackson, M. L. Lee, J. Chromatogr.,289, 105 (1984).
C. P. M. Schutjes, E. A. Vermeer, J. A. Rijks, C. A. Cramers, in Proceedings of the Fourth International Symposium on Capillary Chromatography,R. E. Kaiser (Editor), Hüthig, Heidelberg, Germany, 1981, pp. 687–702.
C. P. M. Schutfes, E. A. Vermeer, J. A. Rijks, C. A. Cramers, J. Chromatogr.253, 1 (1982).
G. Gasper, R. Annino, C. Vidal-Madjar, G. Guiochon, Anal. Chem.50, 1512 (1982).
R. C. Kong, M. L. Lee, J. High Resoln. Chromatogr./Chromatogr. Commun.6, 319 (1983).
R. C. Kong, M. L. Lee, Chromatographia17, 451 (1983).
C. P. M. Schutjes, E. A. Vermeer, C. A. Cramers, in Fifth International Symposium on Capillary Chromatography, Riva del Garda, Italy, April 20–28, 1983, pp. 29–39.
T. Welsch, W. Engewald, C. Klaucke, Chromatographia10, 22 (1977).
K. Grob, G. Grob, K. Grob, Jr., J. High Resoln. Chromatogr./Chromatogr. Commun.2, 31 (1979).
G. Schomburg, H. Husmann, H. Borwitzky, Chromatographia12, 651 (1979).
T. J. Stark, R. D. Dandeneau, L. Mering, 1980 Pittsburgh Conference, Abstract 002, Atlantic City, New Jersey, (1980).
L. Blomberg, K. Markides, T. Wannman, J. High Resoln. Chromatogr./Chromatogr. Commun.4, 527 (1980).
L. Blomberg, K. Markides, T. Wannman, in Proceedings of the Fourth International Symposium on Capillary Chromatography,R. E. Kaiser (Editor). Hüthig, Heidelberg, 1981, pp. 73–90.
B. W. Wright, P. A. Peaden, M. L. Lee, T. J. Stark, J. Chromatogr.248, 17 (1982).
J. C. Fjeldsted, R. C. Kong, M. L. Lee, J. Chromatogr.279, 449 (1983).
Author information
Authors and Affiliations
Additional information
Dedicated to Professor S. R. Lipsky on the occasion of his 60th birthday.
Rights and permissions
About this article
Cite this article
Kong, R.C., Woolley, C.L., Fields, S.M. et al. Deactivation of small-diameter fused-silica capillary columns for gas and supercritical fluid chromatography. Chromatographia 18, 362–366 (1984). https://doi.org/10.1007/BF02262481
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02262481