The efficiency of a pilot U scintillator for neutrons in the energy range 55–225 MeV

https://doi.org/10.1016/0029-554X(79)90572-XGet rights and content

Abstract

The absolute efficiency for detection of neutrons in a Pilot U scintillator 76 mm long and 114 mm diameter has been measured at En = 55, 71, 107, 110, 162 and 225 MeV. The results are in good agreement with the predictions of a Monte Carlo simulation of the detection process provided that the detection threshold is chosen appropriately.

References (4)

  • A.N. James et al.

    Nucl. Instr. and Meth.

    (1977)
  • C. Amsler et al.

    Nucl. Instr. and Meth.

    (1978)
There are more references available in the full text version of this article.

Cited by (7)

  • A neutron hodoscope for medium energy np scattering experiments

    1991, Nuclear Inst. and Methods in Physics Research, A
  • Quasi-free nucleon scattering on <sup>16</sup>O

    1986, Nuclear Physics, Section A
View all citing articles on Scopus

Work supported in part by a grant from The National Research Council of Canada.