Position and angle resolving light ion detector for the Q3D magnetic spectrograph

https://doi.org/10.1016/0168-9002(90)90220-ZGet rights and content

Abstract

A light ion focal plane detector of 1.2 m length using single wire proportional detectors and cathode readout is described. Focal plane reconstruction and vertical position determination is achieved. Good background reduction and 0.6 mm FWHM detector resolution has been obtained with standard electronic setup. In operation with the spectrograph a 2.7 keV linewidth has been observed for elastic scattering of 20 MeV deuterons from a 50 μg/cm2 Au-strip target, 0.5 mm wide.

References (8)

  • R. Hertenberger et al.

    Nucl. Instr. and Meth.

    (1987)
  • M. Löffler et al.

    Nucl. Instr. and Meth.

    (1973)
  • H.J. Scheerer
  • H. Wessner
There are more references available in the full text version of this article.

Cited by (19)

View all citing articles on Scopus

Work supported in part by the BMFT.