Preliminary measurements of SIS 18 beam parameters

https://doi.org/10.1016/0168-9002(92)90190-FGet rights and content

Abstract

The performance of the newly commissioned heavy-ion synchrotron SIS 18 is investigated. The fragment separator provides access to all six phase-space coordinates of the slowly extracted ion beam. Transverse beam emittances were found to be ϵxx = 1.8π mm mrad and ϵyy = 4.0π mm mrad for 40Ar at 1 GeV/nucleon. A change in longitudinal momentum over extraction time is discussed. The stability of mean position and angle during resonance extraction is investigated.

References (6)

  • H. Stelzer
  • P. Kienle
  • B. Franczak
There are more references available in the full text version of this article.

Cited by (12)

  • Depth dose measurements in water for <sup>11</sup>C and <sup>10</sup>C beams with therapy relevant energies

    2022, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • The scintillation-detector equipment of the GSI projectile-fragment separator

    1995, Nuclear Inst. and Methods in Physics Research, A