Comparative study of new 130 mm diameter fast photomultipliers for neutron detectors
References (19)
- et al.
Nucl. Instr. and Meth.
(1988) - et al.
Nucl. Instr. and Meth.
(1991) - et al.
Nucl. Instr. and Meth.
(1982) - et al.
Nucl. Instr. and Meth.
(1984) - et al.
Nucl. Instr. and Meth.
(1987) - et al.
Nucl. Instr. and Meth.
(1983) - et al.
Nucl. Instr. and Meth.
(1979) - et al.
Nucl. Instr. and Meth.
(1982) - et al.
Nucl. Instr. and Meth.
(1983)
Cited by (31)
ELIGANT-GN — ELI Gamma Above Neutron Threshold: The Gamma-Neutron setup
2022, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentCitation Excerpt :This type of liquid has been extensively used in neutron detector systems for nuclear structure measurements, for example in the EUROBALL Neutron Wall [42] or the NEutron Detector Array (NEDA) setup [43–45]. The typical value for the number of photo-electrons per MeV for this kind of detector combination is approximately 900 [47,48]. This value can vary with the quality of the photocathode, the light collection and absorption properties of the detector cell, as well as the quality of the liquid itself.
Neutron detection and γ-ray suppression using artificial neural networks with the liquid scintillators BC-501A and BC-537
2019, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentStudy of n-γ discrimination by zero-crossing method with SiPM based scintillation detectors
2018, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentDigital pulse-timing technique for the neutron detector array NEDA
2015, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentTest of digital neutron-gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)
2014, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentCitation Excerpt :The Nphe depends on the number of photons per MeV, light collection from the scintillator, and the quantum efficiency of the photocathode. The Nphe per energy unit was measured by comparing the position of the peak corresponding to a single photoelectron to the position of the Compton edge of γ-ray emitted by a 137Cs source [37]. The results of the Nphe measurement for the four PMTs are shown in Table 2.
NSTAR-A capture gated plastic neutron detector
2011, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated EquipmentCitation Excerpt :The XP2041 photomultipliers were selected from the available inventory mainly because of their sensitivity to the scintillation light emitted by BC-408 and a sufficiently fast rise time of 2 ns, making them applicable in time-of-flight measurements. However, newer photomultiplier types are commercially available [14], which offer similar or superior performance for the present application. Direct photo multiplier attachment or coupling to the stack via conical light guides both gave good light output collection.