Letter to the editor
Precision measurement of target position during irradiation

https://doi.org/10.1016/0168-9002(88)90848-0Get rights and content

Abstract

We have developed a technique to measure the position of thin target foils (≤ 10 μm/cm2) during irradiation with an accuracy of ∼ 7 μm. The experiment makes use of a kinematic coincidence technique, recording the scattered as well as the recoil particles in a precisely known geometrical setup. For 3 μm/cm2 carbon foils bombarded by 4 MeV 12C2+ ions, target foil movements of about 4 μm/h were observed.

References (6)

  • P. Sigmund et al.

    Nucl. Instr. and Meth.

    (1974)
  • P. Maier-Komor

    Nucl. Instr. and Meth.

    (1972)
  • C.J. Sofield et al.

    Nucl. Instr. and Meth.

    (1981)
There are more references available in the full text version of this article.

Cited by (2)

Permanent address: Institute for Nuclear Studies, Hoza 69, Warsaw, Poland.

∗∗

Present address: Gesellschaft für Schwerionenforschung GSI, Darmstadt, FRG.