The spatial resolution of the time projection chamber at triumf

https://doi.org/10.1016/0167-5087(84)90215-1Get rights and content

Abstract

The spatial resolution of the time projection chamber at TRIUMF has been investigated. The best resolution, σ ⋍ 200 μm, occurs at the minimum drift length and for an optimum track to anode crossing angle determined by the magnetic field. The resolution worsens for tracks crossing at larger or smaller angles and for longer drift lengths. The observed resolution is quantitatively reproduced by considering the diffusion of the drifting electrons, the track to anode crossing angle, E × B effects near the anode wire and the discrete nature of the ionization process.

References (6)

  • Proposal for a PEP Facility Based on the Time Projection Chamber. D.R. Nygren spokesman

    PEP Experiment No. 4, SLAC PUB-5012

    (1976)
  • C.K. Hargrove

    Phys. Scripta

    (1981)
    M. Blecher

    Search for Muon-Electron Conversion at TRIUMF

    C.K. Hargrove
  • We are grateful to the Enrico Fermi Institute of the University of Chicago and Professor H.L. Anderson and S.C. Wright...
There are more references available in the full text version of this article.

Cited by (0)

Also at the University of Victoria.

∗∗

Also at the University of British Columbia.