Test results of an electromagnetic calorimeter with 0.5 mm scintillating fibers readout

https://doi.org/10.1016/0168-9002(94)91099-5Get rights and content

Abstract

We report on an experimental study of the performance of an electromagnetic calorimeter consisting of thin (0.5 mm diameter) scintillating plastic fibers embedded in lead. Because of the small sampling fraction (3.5% for minimum ionizing particles), this detector is quite compact, with an effective radiation length of 7.2 mm and a Molière radius of 20 mm. Because of the very frequent shower sampling provided by the fibers, the energy resolution is nevertheless good: 9.2%/√E(GeV) for electromagnetic (e.m.) showers, with a small, angle dependent constant term. A non-uniformity in the response is observed at the 2% level across the calorimeter. In spite of the small sampling fraction the light yield is not a limiting factor in this calorimeter: we measured ∼ 500 photoelectrons per GeV shower energy. The position resolution for electrons and two e.m. showers separation have been studied. The fibers sticking out of the back of the detector do not appear to affect the measurements of hadronic showers.

References (25)

  • F.G. Hartjes et al.

    Nucl. Instr. and Meth. A

    (1989)
  • D. Acosta

    Nucl. Instr. and Meth. A

    (1991)
  • D. Acosta

    Nucl. Instr. and Meth. A

    (1991)
  • D. Acosta

    Nucl. Instr. and Meth. A

    (1992)
  • D. Acosta

    Nucl. Instr. and Meth. B

    (1991)
  • R. Wigmans

    Nucl. Instr. and Meth. A

    (1987)
  • D. Acosta

    Nucl. Instr. and Meth. A

    (1991)
  • D. Acosta

    Nucl. Instr. and Meth. A

    (1991)
  • D. Acosta

    Nucl. Instr. and Meth. A

    (1992)
  • B. Bencheikh

    Nucl. Instr. and Meth. A

    (1992)
  • B. Bencheikh

    Nucl. Instr. and Meth. A

    (1992)
  • D. Hertzog

    Nucl. Instr. and Meth. A

    (1990)
  • Cited by (13)

    • The FOREST detector for meson photoproduction experiments at ELPH

      2016, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • Sampling calorimetry

      2002, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • Beam test results from a fine-sampling quartz fiber calorimeter for electron, photon and hadron detection

      1997, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • Separation of γ/π<sup>0</sup> showers at high energies

      1997, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • The H1 lead/scintillating-fibre calorimeter

      1997, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    • Beam test results from the SPAKEBAB electromagnetic calorimeter

      1996, Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    View all citing articles on Scopus
    1

    3HF (200)+PTP, polystyrene base,Kuraray Company.

    View full text