Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Electronic Resource  (3)
  • 2025-2025
  • 2000-2004  (3)
  • 1980-1984
  • 1955-1959
  • 1945-1949
  • 1920-1924
  • 1900-1904
  • 1880-1889
  • 1860-1869
  • 1830-1839
  • 1810-1819
  • 2004  (1)
  • 2002  (2)
  • 1949
  • 1945
  • 1920
  • 1882
  • 1869
  • 1868
  • 1863
  • 1862
  • 1834
  • 1814
  • PACS. 45.70.-n Granular systems – 47.54.+r Pattern selection; pattern formation  (2)
  • Breast reduction  (1)
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Aesthetic plastic surgery 20 (2004), S. 391-397 
    ISSN: 1432-5241
    Keywords: Breast reduction ; Breast tumors ; Breast tumor screening ; Mammography ; Ultrasound
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract We conducted a retrospective study to evaluate the diagnosability of breast tumors after breast reductions as this is a frequent surgical procedure. The data should shed light on the hypothesis that routine screening methods concerning the diagnosis of breast tumors prove more difficult after breast operations. All women who had undergone breast reduction at our department between January 1989 and December 1994 were examined. During this period we counted 166 patients; the majority of them (n = 144) had undergone a bilateral breast reduction and the rest of them (n = 22) a unilateral breast reduction for various reasons. After the operation, all patients were checked in standardized intervals. Those who developed any kind of breast mass (n = 6) were recorded and examined by ultrasound and mammography, and occasionally by an additional fine-needle biopsy. In case any doubt about the dignity had remained, an excisional biopsy was carried out. In none of our patients was it possible to get a precise diagnosis of an ill-defined mass with ultrasound. With mammography, some of the existing masses, which were really scars, mimicked different kinds of tumors, and once a carcinoma was initially interpreted as scar tissue with oil cysts. The diagnosis of breast masses after breast reductions with routinely used screening methods has proved to be more difficult as breast reductions lead to architectural alterations of the remaining breast parenchyma. Such alterations can and should be documented shortly after the operation so that later occurring tumors are distinguished more easily. Therefore, a basic mammography 3 months after each breast reduction has to be claimed in order to facilitate further breast tumor diagnosis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 28 (2002), S. 321-339 
    ISSN: 1434-6036
    Keywords: PACS. 45.70.-n Granular systems – 47.54.+r Pattern selection; pattern formation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: Almost fifty years of investigations of barchan dunes morphology and dynamics is reviewed, with emphasis on the physical understanding of these objects. The characteristic quantities measured on the field (shape, size, velocity) and the physical problems they rise are presented. Then, we review the dynamical mechanisms explaining the formation and the propagation of dunes. In particular a complete and original approach of the sand transport over a flat sand bed is proposed and discussed. We conclude on open problems by outlining future research directions.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 28 (2002), S. 341-352 
    ISSN: 1434-6036
    Keywords: PACS. 45.70.-n Granular systems – 47.54.+r Pattern selection; pattern formation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: We present in this paper a simplification of the dune model proposed by Sauermann et al. which keeps the basic mechanisms but allows analytical and parametric studies. Two kinds of purely propagative two dimensional solutions are exhibited: dunes and domes. The latter, by contrast to the former, do not present a slip face. Their shape and velocity can be predicted as a function of their size. We recover that dune profiles are not scale invariant (small dunes are flatter than the large ones), and that the inverse of the velocity grows almost linearly with the dune size. We furthermore get the existence of a critical mass below which no dune solution exists. It rises the problem of dune nucleation: how can dunes appear if any bump below this minimal mass gets eroded and disappears? The linear stability analysis of a flat sand bed shows that it is unstable at large wavelengths: dune can in fact nucleate from a small sand mass if the proto-dune is sufficiently long.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...