Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Archives of toxicology 54 (1983), S. 311-321 
    ISSN: 1432-0738
    Keywords: Toxaphene ; Distribution ; Mice ; Autoradiography ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Series of female virgin and pregnant albino mice were i.v. injected with14C-labelled- or unlabelled toxaphene (16 mg/kg b.w.). After survival times ranging from 1 min to 32 days the toxaphene distribution in the body was studied using whole-body autoradiography and capillary gas-chromatography. Autoradiographic studies have shown that after an initial accumulation in the liver, brown fat, lung, brain, kidney, and ovaria (corpora lutea) there was a gradual redistribution of radioactivity to the white fat within 4 h postinjection. The labelling was then decreasing rapidly and only negligible amounts of the radioactivity were present in the adipose tissue after 32 days. In the fetus only the liver and adrenals showed a distinct labelling. A specific and persistent accumulation of the label was detected in some zones of the adrenal cortex suggesting a possible direct interference of toxaphene with adrenal steroid hormone synthesis. The gas chromatographic pattern of toxaphene-derived residues in the tissue samples resembled that of the technical toxaphene, but was changing in different tissues with the time. The liver chromatograms indicated more extensive formation of metabolites.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    International archives of occupational and environmental health 53 (1983), S. 101-108 
    ISSN: 1432-1246
    Keywords: Biological exposure test ; Exercise ; Gas chromatography ; Hippuric acid ; Humans ; Isotachophoresis ; Laboratory exposure ; o-Cresol ; Rest ; Toluene ; Urine
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Summary The urinary excretion of hippuric acid and o-cresol was studied after respiratory exposure of human volunteers to approximately 80 ppm (306 mg/m3 ± SD 13) of toluene for 2 h under different work loads (0, 50,100, 150 W, respectively, during 30-min periods). The diet before and after exposure varied. An isotachophoresis method for the determination of hippuric acid is described. The correlation between the total urinary excretion, excretion rate and concentration of hippuric acid, and the respiratory uptake of toluene was poor or non-existing. The same was true for the excretion of o-cresol, which 4 h after exposure was concluded amounted to 0.03–0.26% of the toluene uptake. Thus, after a short-time exposure neither metabolite proved to be a reliable measure of individual toluene uptake at varying workloads or food intake in combination with low exposure levels.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1432-1238
    Keywords: Gas chromatography ; Head-space analysis ; CCl4 intoxication ; Hyperventilation therapy
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract A head-space gas chromatographic method for the determination of carbon tetrachloride in human blood is described. Standard samples with 0.5 ml whole blood containing different concentrations of CCl4 were analyzed at column temperatures ranging from 50° to 90°C. Advantages of this method include high sensitivity, simplicity in handling, rapid achievement of reliable results, accuracy and low costs. The practicability of this analytical method was studied in a patient following suicidal oral ingestion of a lethal dose of carbon tetrachloride.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1432-2072
    Keywords: Halazepam ; Desmethyldiazepam ; Benzodiazepines ; Pharmacokinetics ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract Halazepam and its major metabolite desmethyldiazepam (DMDZ) can be reliably quantitated in human plasma following single doses of halazepam. After addition of appropriate internal standards, halazepam and DMDZ are extracted directly into an organic solvent at physiological pH. The organic extract is separated, evaporated to dryness, reconstituted, and directly chromatographed using a 50:50 methyl:phenyl silicone column (SP-2250) and an electron-capture detector. After a single 40 mg oral dose of halazepam, the parent compound appears in plasma only transiently and at low levels. DMDZ appears in higher concentrations and is slowly eliminated. During multiple-dose therapy with halazepam, DMDZ will be the major active substance in blood.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 5
    Electronic Resource
    Electronic Resource
    Springer
    Entomologia experimentalis et applicata 34 (1983), S. 20-26 
    ISSN: 1570-7458
    Keywords: Dioryctria abietella ; Cone pyralid ; Lepidoptera ; Pyralidae ; Sex pheromone, (Z,E)-9,11-tetradecadienyl acetate ; Single sensillum recordings ; Electroantennography ; Gas chromatography ; Mass spectrometry
    Source: Springer Online Journal Archives 1860-2000
    Topics: Biology
    Description / Table of Contents: Résumé L'analyse en chromatographie gazeuse associée à une détection électroantennographique a montré que l'acétate (Z,E)-9,11-tétradécadiényle (Z,E)-9,11–14:Ac est l'un des composants de la phéromone de Dioryctria abietella Schiff (Lepid.: Pyralidae). Couplage chromatographie en phase gazeuse spectrometrie de masse a montré la présence d'acétate tétradécadiényle avec un spectre de masse et un indice de rétention identiques au Z,E-9,11–14:Ac Un récepteur cellulaire sensible à la fois au Z,E-9,11–14:Ac et à un extrait de la femelle a été identifié sous l'antenne du mâle. Les analyses des antennogrammes et de la cellule isolée ont étayé la caractérisation du composant de la phéromone comme étant Z,E-9,11–14:Ac. Un récepteur cellulaire additionnel sensible à l'acétate (Z.)-9-tétradécadiényle et à l'acétate (Z.E.)-9,12-tétradécadiényle a été trouvé sur l'antenne du mâle, mais il n'était pas activé par l'extrait de la femelle. Sur le terrain Z,E-9,11–14:Ac, présenté seul, attirait des nombres importants de mâles de D. abietella. L'addition de l'acétate (Z)-9-tétradécényle a inhibé l'attraction des mâles par les pièges.
    Notes: Summary Gas chromatographic analyses coupled with electro-antennographic detection indicated that (Z,E)-9,11-tetradecadienyl acetate (Z,E-9, 11–14:Ac) is a pheromone component of the cone pyralid Dioryctria abietella. Gas chromatographic-mass spectrometric analyses confirmed the presence of a tetradecadienyl acetate with mass spectrum and retention index identical to Z,E-9,11–14:Ac. A receptor cell sensitive to both Z,E-9,11–14:Ac and the female extract was identified on the male antenna. An additional receptor cell sensitive to (Z)-9-tetradecenyl acetate and (Z,E)-9,12-tetradecadienyl acetate was found on the male antenna but was not activated by the female extract. In the field Z,E-9,11–14:Ac presented alone attracted significant numbers of male D. abietella. Addition of (Z)-9-tetradecenyl acetate inhibited the attraction of males to traps.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; GC-FTIR
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The performance of a column prepared with an immobilized (chemically bonded) methylsilicone phase having a film thickness of 5μm is investigated in detail. Due to their high sample capacity, such columns are particularly useful when directly coupling gas chromatography with spectroscopic techniques such as Fourier-transform infrared spectroscopy. Thick-film columns can even be used with thermal conductivity detectors.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 241-243 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Detectors ; Flame ionization detector ; History of chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary On the occasion of the 25-year anniversary of its invention, this article summarizes the events which led to the development of the flame ionization detector.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 472-476 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid stationary phase ; Liquid phase bleeding
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The theory of the evaporation of the liquid stationary phase is elaborated and experimentally verified. On the basis of this theory the role played by the losses in the amount of liquid phase present is quantitatively determined. General techniques are examined which minimize the losses; these techniques are based on saturating the incoming carrier gas with liquid phase vapours and raising the pressure of the carrier gas in the column, e.g. by connecting a capillary to the column outlet in order to offer resistance to the gas flow. The application of these techniques ensures stable performance of the gas chromatographic columns using a volatile liquid phase.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 33-36 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Preparative scale chromatography ; Capacity ; Dual-step separation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The capacity of dual-step preparative chromatographic separation systems is considered. It is shown that dualstep separation makes it possible to enhance the capacity of preparative installations as compared with single- and dual-stage purification of the compounds.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 418-420 
    ISSN: 1612-1112
    Keywords: Separation of metal chelates ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A very good separation of the acetylacetonate of AL-(III), Cr(III) and Co(III) has been obtained by gas chromatography, on a column containing OV-17 silicone oil as the stationary phase.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 11
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 421-425 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Purge and trap sampling ; Cryogenic focussing ; Water analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The most important operating parameters of a commercial purge and trap GC apparatus have been investigated. Band broadening problems arising from the slow desorption of compounds from the Tenax trap have been overcome by cryogenic focussing at the beginning of the column. Good results have been obtained with both packed and capillary columns. The sensitivity of the technique is sufficient to detect benzene in water at concentrations below 1μg kg−1 (1 ppb).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 12
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 65-69 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Oxygenates ; Fused-silica capillary columns
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A method of analysing gasolines that contain oxygenates has been developed. The method uses a single fusedsilica capillary column and gives quantitative data for the oxygenates and the hydrocarbons in one analysis.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 13
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 600-604 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Alkyl benzenes
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The additivity concept in the retention index system of Kovats has been examined for a series ofn-alkylbenzenes and theiro- andp-monosubstituted nitro-, amino-, and chloro-derivatives. Anomalous behaviour is exhibited by the first three members of the series on both polar and non-polar stationary phases. For addition of a methylene group ton-propylbenzene or ap-substituted derivative, it is found that the retention increment, Δl CH2, approaches 100 units. However, the strong inductive effect of the group in the ortho position and the steric effects apparent in ano-substituted alkylbenzene lead to large variations of retention increment upon addition of-CH2-to the alkyl chain. A study ofn-alkylbenzene retention on Apiezon L and Carbowax 20M over a wide range of temperatures has verified the linearity of the retention increment with temperature and has revealed that this gradient increases with increasing carbon side-chain length for the first few members of the series, thereafter becoming constant. Functional retention increments, Δlx, for substitution of nitro-, amino- and chloro-groups into the benzene ring are given.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 14
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 191-194 
    ISSN: 1612-1112
    Keywords: Thermal treatment of MgO and MgCO3 ; Adsorption properties ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The changes in the chromatographic properties of MgO and MgCO3 due to thermal treatment was investigated. The experimental results show that thermally treated MgO and MgCO3 can be used as stationary phase for the gas-adsorption chromatography of hydrocarbon mixtures.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 15
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; n-Butyl esters of fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The esterification of C1−C8 fatty acid in aqueous solutions and in the presence of sulfuric or hydrochloric acid and with n-butanol is described. It has been established that the esterification can be used for the quantitative determination of these fatty acids in the concentration ratio range of [H2O]/[n-BuOH]=0.01–5.3. In the concentration ratio range of 0.01–0.8 the water present does not interfere. In the concentration range of above 0.8 anhydrous sodium sulfate is used for binding the water, in the amount of [Na2SO4.anh.]/[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 16
    ISSN: 1612-1112
    Keywords: Esterification in aqueous solution ; iso butyl esters of C1–C20 fatty acids ; Gas chromatography ; Fatty acid analysis
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary C1–C20 carboxylic acids have been esterified in aqueous solutions with i-butanol. Gas chromatographic analyses have been performed from a single chromatogram. It has been established that esterification in the concentration range of [H2O]/[i-BuOH]=0.01–10.3 can be utilized for the quantitative determination of these carboxylic acids. The presence of water does not interfere in the range of [H2O]/[i-BuOH]=0.01–1.03. In the cases of [H2O]/[i-BuOH]〉1.03, anhydrous sodium sulfate has been used for binding the water, in an amount of [Na2SO4]anh./[H2O]≥0.2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 17
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 44-46 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Natural gas analysis ; Poropak N
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary A simple gas chromatographic method is described for the rapid analysis of natural gas using thermal conductivity detectors and programmed-temperature operation of a single Poropak N column. The method permits the determination of nitrogen, carbon dioxide and hydrocarbons containing one to seven carbon atoms.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 18
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 553-559 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Open-tubular (capillary) columns ; Immobilized liquid phases ; Thick-film columns ; Diffusion coefficients
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The influence of the liquid phase film thickness in open-tubular (capillary) columns on the individual resistance-to-mass-transfer terms and on the overall column efficiency is examined from the theoretical point of view. Methods for the calculation of the diffusion coefficients are discussed.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 19
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 691-692 
    ISSN: 1612-1112
    Keywords: Dichlorophenol isomers ; Sodium benzenesulfonate ; Gas chromatography
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary It is difficult to separate all the dichlorophenol isomers as free phenols by gas-liquid chromatography. However they were effectively separated on 4,4′-dimethoxyazoxybenzene (liquid crystal), and all the isomers were separated appreciably well on sodium 1-naphthalenesulfonate, 2-naphthalenesulfonate and dodecylbenzenesulfonate.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 20
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Trace analysis ; GC-concentration ; Enrichment factor ; Theoretical evaluation
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Based on gas chromatographic retention data obtained on a given adsorbent and at a given trap efficiency at different temperatures new equations are proposed for the evaluation of the enrichment factor. These equations are suitable under various preconcentration conditions such as: equilibrium saturation, complete trapping and permissible losses. Compared to known expressions for the evaluation of the enrichment factor the equations suggested consider the band broadening of the impurity in a trap causing a loss of the substance at the adsorption stage and dilution of the sample during desorption when the desorbed impurities are directed into the gas chromatographic column without intermediate freezing out in an graphic column without intermediate freezing out in an empty tube. The new equations may be used to select the optimum preconcentration conditions providing the necessary sensitivity.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 21
    Electronic Resource
    Electronic Resource
    Springer
    Chromatographia 17 (1983), S. 269-284 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Liquid chromatography ; Phenols
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Gas and high-performance liquid chromatographic methods in the analysis of phenols are reviewed. Among the great number of phenolic compounds analyzed, alkylphenols, chlorophenols, dihydroxy- and trihydroxybenzenes and biphenols are chiefly considered. The advantages and drawbacks of the methods are discussed, quoting the most important work. Relationships between the structural characteristics of phenols, the stationary phase structure, the mobile phase composition and the retention data are treated. Typical examples of the conditions for GC and HPLC analysis are summarized in tables. The literature comprises over 270 references, most of them recent.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 22
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Average molecular polarizability ; Retention index ; Polycyclic aromatic hydrocarbons
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Abstract The Kováts retention indices of 10 polycyclic aromatic hydrocarbons were determined on SE-30, OV-101, SE-52, OV-7 and OV-17 stationary phases. A significant correlation has been found between the retention indices and the average molecular polarizabilities of the analyzed substances. Equations were derived for the direct determination of the average molecular polarizabilities from the retention index values. The influence of the temperature on this relationship is also indicated.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 23
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 153-155 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Immobilization of moderately polar phases ; Combination of surface bonding and crosslinking ; Vinyl groups in the support surface ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 24
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 101-103 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; GC/MS ; Drugs of abuse ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 25
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 133-139 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Advantages of very thick coatings ; Separation efficiency correlated with film thickness ; Preparation of columns with very thick coatings ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It has become common practice with capillary columns to call film thicknesses of 0.1 - 0.3 μm regular or standard, whereas 0.3 - 1.0 μm is considered to denote thick films. Consequently, films with thickness beyond 1μm (we have explored the range up to 8.0 μm) may be termed very thick. Increasing film thickness, at least to about 5 μm, brings important additionl advantages primarily in terms of loading capacity. Columns with very thick coatings may replace the traditional SCOT columns thanks to at least equivalent loading capacity combined with higher separation efficiency, and better stability characteristics. Additional advantages are increased retention, essential for the analysis of very volatile substances, and increased elution temperature, providing a basis for direct water injection.We observe that TZ (the separation number) drops to roughly 50% when the film thickness is increased by a factor of 300 from 0.025 to 8.0 μm, provided TZ is measured with a standard flow of hydrogen. The reduction is only 30% when the thick-film colums are run with individual optimization with nitrogen as a carrier gas. In contrast to standard columns, very thickly coated columns show slightly increased separation efficiency with nitrogen at drastically reduced flow rate. The HETP increases very slightly in the indicated range of flim thickness. This contradicts widespread theoretical expectations, which probably account for the fact that very thick coatings have so far been neglected. Since the preparation of very thick coatings involves some deviations from the standard procedure, complete and detailed instructions are given.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 26
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 269-272 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Retention indices ; Specific retention volumes ; n-Alkanes ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: The choice of stationary phase for gas chromatography is dictated by the nature of the analytes. Polarity and selectivity are known to play an important role. This paper suggests equations for calculation of specific retention volumes of any compounds from their retention indices.
    Additional Material: 3 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 27
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 279-281 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, glass ; Packed column ; Retention data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 28
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 328-332 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica (capillary) columns ; Bonded (cross-linked ) phases ; Hydrocarbon analysis ; Retention index data ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 29
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Automated analysis ; Solvent vapor ; Gas sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Solvent vapors in air may be measured with capillary gas chromatographic columns. By using large diameter columns and sample loops of approximately the same internal diameter, the column may be connected directly to the gas sampling valve. This approach eliminates the use of a splitter or cryogenic trapping and allows low levels to be measured. By operating the column at high velocity, column efficiency is sacrificed for increase in speed.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 30
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Residue analysis ; Fenvalerate ; Fabric protectant ; Woolen cloth ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A method is described for the determination of fenvalerate (cyano(3-phenoxyphenyl)methyl 4-chloro-α-(1-methylethyl)-benzeneacetate) residues on woolen cloth. The fenvalerate was Soxhlet-extracted from the treated fabric with acetone for four hours at a reflux rate of six solvent exchanges per hour. The fenvalerate residue was determined by gas-liquid chromatography with a flame ionization detector. The results were quantitated by comparing integrator counts obtained from extracts of treated samples with those obtained from known standards. The method was sensitive to 0.00054% fenvalerate by weight. Recoveries from fabric treated with 0.00054% to 0.215% averaged 94.8%. The response of the detector was linear over a 400-fold range of fenvalerate concentrations.
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 31
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 232-235 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Inlets ; Solvent effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 32
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 390-391 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Dispersive interactions ; Inductive interactions ; Polycyclic aromatic hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 33
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 392-393 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Hydrogen carrier gas ; Pt-Ir tubing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 34
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 480-487 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Residue mixtures ; Inlet characteristics ; Injection procedure ; Repeatability ; Linearity ; Quantification ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Residue mixtures of pesticides in foods which were difficult to separate by packed-column gas chromatography were determined by capillary gas chromatography and electron capture detection. Manual injections of sample and reference standard were made with a 10 μL syringe on a septum-enclosed, split/ splitless inlet system. Optimal peak height repeatability (± 3%( was achieved with three-μL injections which were made within time periods of four hours or less. The average linearity coefficient (slope( obtained for detector response as a function of solution concentration was 1.1.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 35
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 504-507 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Effluent splitting ; Polyimide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 36
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 510-511 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Optically active compounds ; Determination of trace amounts ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 37
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 507-509 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, glass ; GC/MS ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 38
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 561-563 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary ; On-column injection ; Rotary valve ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 39
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 621-622 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Multiplex GC ; Vacancy chromatograms ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 40
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 623-624 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 41
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 684-685 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Post column trap ; Alumina ; Halocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 42
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 4-10 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Ion mobility detector ; Plasma chromatography ; Selective detection ; Quantitative analysis ; Halogenated compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: An ion mobility detector that has been specifically developed for interfacing with capillary gas chromatography is investigated in the negative ion mode. Like the electron capture detector, to which this instrument is closely related, the ion mobility detector shows an enhanced response to low molecular weight halogenated compounds when a small quantity of oxygen is doped into the make-up gas flow. Under O2 doping conditions, the device can operate in a reactant ion monitoring mode responding universally to compounds capable of capturing thermal electrons and in a tunable selective product ion mode providing increased selectivity over that achieved by the ECD. At an oxygen concentration of 0.5%, minimum detectable amounts as low as 600 femtograms have been realized for carbon tetrachloride. Selectivity of chloro- versus bromo- compounds is demonstrated using a mixture of p-dichlorobenzene and p-dibromobenzene.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 43
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 34-35 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Samples with varying water content ; Retention times correlated with water content ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 44
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 213-215 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; HPLC sample work-up ; Valeriana celtica L ; Essential oil ; Nepetalactone, isovaleric acid ; Feline attractant ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 45
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 228-231 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Sample introduction ; Splitless injection ; On-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 46
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Dynamic versus static leaching ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: It is well known that removal of metal ions from the glass surface greatly improves both the thermal stability and the adsorption characteristics of glass capillary columns. Usually metal ions are removed from a glass surface by acid leaching; in particular, the static leaching procedure with hydrochloric acid is used very often for the preparation of glass capillary columns. This paper discusses the results of an investigation into dynamic leaching. Special attention is paid to those factors which affect the adsorption properties of the leached surface. The importance of the non-specific adsorptivity of the capillary surface due to changes of surface properties induced by the leaching process is pointed out.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 47
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 317-319 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; Drug screening ; Fused silica capillary column ; Toxicology ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 48
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 319-321 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Supercritical fluid chromatography ; Small diameter capillary columns ; Static coating at elevated temperature ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Tab.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 49
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 247-254 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Screening for basic drugs with retention indices differing by only four units ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Capillary columns offer the toxicologist several advantages over packed columns. We have presented a highly reproducible screening procedure based on the retention index system and have shown the use of capillary columns for routine quantitation. We are currently expanding the use of these columns in our laboratory and predict that they will be in routine use by most toxicologists in the near future.
    Additional Material: 9 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 50
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 422-426 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; Stationary phase, polar ; DEGA ; Residue analysis of pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Polydiethylene glycol adipate (DEGA) has been successfully used as stationary phase for residue analysis by glass capillary gas chromatography. A specially stabilized version of the phase yields a good polar column which is stable up to 250°C when used in temperature programmed cycles. The paper lists 90 pesticides that have been successfully chromatographed in ng quantities on a DEGA column.
    Additional Material: 10 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 51
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 436-440 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Superox-4 pretreatment, deactivation ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 52
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 442-443 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Cyclodextrin polymer beads ; Double retention mechanism ; Interaction energy ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 53
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 444-445 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Open-tubular columns ; Reduced diameter ; High pressure ; Coating reservoir ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 54
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 448-450 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Solute focussing ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 55
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 501-504 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Van Deemter curves ; Thick film columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 56
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 497-500 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column, fused silica ; On-column injection ; Solvent polarity ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 57
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 564-565 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, fused silica ; Splitless injection ; Trace analysis ; EPA phenols ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 58
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 567-568 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solvent effect ; Headspace analysis ; Trace analysis ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 59
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 595-604 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; GC/MS ; Pyrolysis GC ; Pyrolysis MS ; Headspace sampling ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Pyrolysis gas chromatography (P/GC) has been successful in differentiating coal tar pitches which are used in the manufacture of high temperature graphite materials [1,2]. In the present study, coal tar and petroleum pitches received from five suppliers were readily differentiated using three distinct methods of polymer analysis: dynamic headspace and pyrolysis gas chromatography mass spectrometry (DH/GC/MS and P/GC/MS, [3]), and pyrolysis mass spectrometry (P/MS, [4,5]). All of these methods are appropriate for the analysis and pattern recognition study of coal and petroleum products; however, methods which incorporate GC usually necessitate long analysis times and are subject to problems associated with gas chromatographic reproducibility (e.g. active sites [6], and nonconstant retention times). As a fingerprint analysis method, P/MS is rapid and ideally suited to computerized pattern recognition study of pitches due to the simple format of P/MS data (computer tabulation of normalized intensities versus masses); whereas, in the present study, the normalized peak area versus retention time date from DH/GC/MS and P/GC/MS analyses were not suitable for direct input to a computerized pattern recognition analysis program, (due to non-constant retention times and improper data format). One limitation is that P/MS does not provide positive identification of thermally evolved products (as can DH/GC/MS and P/GC/MS) due to the complexity of the spectra of a mixture of compounds produced by P/MS. Within the limits of the commercial instrumentation and computer programs used in this study, a combination of all three techniques provided the greatest capability for the differentiation of the five coal tar and petroleum based pitches studied.
    Additional Material: 16 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 60
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 661-665 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injector systems ; On-column injection ; Liquid chromatography, HPLC ; Dibenzothiophene oxide and dioxide ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Analytical methods are described for identification and monitoring of the oxygenated metabolites of dibenzothiophene. Since such compounds are thermolabile, GC analysis is seen to be hardly feasible with conventional injectors such as all-glass moving needle or splitless injectors. Only on-column injection gives no degradation products. In addition, reversed-phase HPLC is particularly suitable for the analysis of the sulfone or sulfoxides of dibenzothiophenes.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 61
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 680-682 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Split injector ; Herbicides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 62
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 690-693 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Selective on-column injection ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 63
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 36-37 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cryogenic focusing ; On-column, pre-column trapping ; Volatile aroma compounds ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 64
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 11-15 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass ; ECD ; Halocarbons in water, 0.1-10 ppb ; 0.5-2 μl injected on-column ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Interest in monitoring halogenated organics in drinking water and natural surface and ground water in the low ppb range continues to grow. There is a tendency to include still more volatile halocarbons, the trace determination of which is known to be rather demanding. This prompted us to re-examine the feasibility of large-volume direct aqueous injection onto capillary columns, coupled with ECD. A primary problem was to avoid simultaneous elution of water with halocarbons, since water suppresses the ground current of the ECD. The following measures contributed to the solution of this problem.Apolar, extremely inert, columns are required to elute water completely, and even before very light halocarbons. Their coatings have to be far thicker (≍ 5 mUm) than commonly employed thick films since they must permit isothermal analysis at a column temperature around 100°C in order to ensure rapid and complete elution of water. Finally, it is essential that sampling be carried out on-column for two reasons: diffusion of water vapor in the injector, resulting in delayed elution, is then eliminated, and peak distortion during splitless injection is avoided.Although we now know that persilylated columns with immobilized coatings withstand routine water injections, more longterm experience is needed to provide detailed recommendations for the handling of these columns.
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 65
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 40-42 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; Splitless Injection ; Drug analysis ; Concentration dependence of retention values ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 66
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 386-387 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary columns ; On column injection ; Movable injector ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 67
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 42-44 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Mg(NO3)2 .6H2O as stationary phase ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 68
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 60-63 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary column ; Cold silanization ; Medium polarity columns ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Silane-coupling agents, commonly used for fiberglass reinforced plastics (FRP), were applied for deactivation of silanol sites in glass capillary columns prior to coating with mediumpolarity phases such as Carbowax and Superox. The columns, prepared in a two-stage process in the case of glass (acidic leaching and drying, dynamic cold silanization followed by static coating with the phase) or a one stage process in the case of fused silica, gave the best results when deactivation and hence wettability were induced by glycidoxypropyltrimethoxy silane.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 69
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 241-246 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; Cobalt-60 gamma radiation ; Immobilized phase ; Crosslinking ; Column activity ; Temperature Stability ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Fused silica capillaries deactivated with D4 and coated with OV-1 were subjected to cobalt-60 gamma radiation in order to elucidate the effect of incident radiation on column performance. The chromatographic performance of these open tubular columns in which OV-1 was polymerized in situ was found to be dependent on the dosage of radiation and was evaluated before and after the irradiated columns were rinsed with solvent. Of the radiation dosages employed, 3 MRad produced superior chromatographic performance coupled with very favorable residual surface activity.
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 70
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 185-188 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Injection ; Inlets ; Volume overloading ; Concentration overloading ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 71
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 281-282 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Si-OR, bonded stationary phase ; Change of physical state ; Retention mechanism ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 3 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 72
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 255-263 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Capillary, glass, fused silica ; Two-dimensional technique ; Residue analysis in food ; Organophosphorus pesticides ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Two-dimensional gas chromatography with two capillary columns of different polarity (SP 2100 and OV 225) is used for pesticide residue analysis in food samples. By means of “live chromatography” applying pneumatic switching technique according to Deans, unequivocal identification of 57 organophosphorus pesticides in food samples is achieved at trace concentrations. The instrument is equipped with only one injection port and one flame photometric detector. On-line data processing is very helpful, especially in calibration and checking the system's reliability with the multitude of test compounds. The complete pesticide residue analysis including clean-up of about six food samples can be completed by one person in 8 hours.
    Additional Material: 6 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 73
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 366-370 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary column ; Chiral phase ; Amino acid enantiomers ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Heliflex Chirasil-Val, a modified form of the original Chirasil-Val phase coated on fused silica capillary, has been investigated with regard to its resolution efficiency and the separation profile for various enantiomeric derivatives of amino acid. The best results could be obtained with TFA-Et derivatives by reason of the relatively low column temperature required.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 74
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 388-389 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary micro-packed columns ; Separation characteristics ; Application ; Separation of hydrocarbons ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 2 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 75
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 273-274 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Solvent effect ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Additional Material: 1 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 76
    Electronic Resource
    Electronic Resource
    Weinheim : Wiley-Blackwell
    Journal of High Resolution Chromatography 6 (1983), S. 292-299 
    ISSN: 0935-6304
    Keywords: Gas chromatography ; Fused silica capillary columns ; GC/MS/DS ; Cryotrapping of organics ; Cryofocusing of organics ; Trace organic analysis ; Priority pollutants ; Chemistry ; Analytical Chemistry and Spectroscopy
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: A 30 m, 0.25 mm ID, fused silica capillary column at temperatures from -60 to -100°C has been shown to be a quantitative trap for organic compounds with volatilities ranging from that of 1, 1 -dichloroethene that of chlorobenzene. This type of “whole column cryotrapping” provided sharp peaks (peak width approximately 4-7 seconds) for all compounds at a trapping temperature of -80°C and with high carrier gas pressures and linear velocities (30 psi and 110 cm/s, respectively). Whole column cryotrapping possesses great simplicity, chromatographic efficiency (no trapping loop connections), and a built-in indicator of quality assurance for trapping efficiency (i.e., peak shape). These advantages are extremely attractive and are indicative of the fact that the potential of this approach has not yet been fully appreciated.
    Additional Material: 4 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...