    New York : Wiley-Blackwell
    Journal of Bioluminescence and Chemiluminescence 8 (1993), S. 21-24 
    ISSN: 0884-3996
    Keywords: Chemiluminescence ; haemodialysis ; oxalate determination ; urolithiasis ; peroxyoxalate chemiluminescence ; ascorbic acid ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Chemistry and Pharmacology
    Notes: We describe a new sensitive and specific method for determination of oxalate in human serum. By using the chemiluminescence decay of monoperoxyoxalic acid very low concentrations of oxalate (200 nmol/L) can be determined. The mean serum oxalate level in apparently healthy controls was 14.5 ± 8.5 m̈mol/L. Supplementation of ascorbic acid leads to an increase in serum oxalate level. While serum oxalate concentrations of calcium oxalate stone formers (x = 16.4 ± 9.8 m̈mol/L) are not significantly different from the control group, an extreme increase of serum oxalate is evident in haemodialysis patients. The serum oxalate concentration decreased during dialysis treatment from 141.4 ± 32.1 m̈mol/L to 36.4 ± 12.7 m̈mol/L.
    Additional Material: 3 Ill.