Many rectification processes are used to separate corrosive substances with high boiling points. This reports deals with a new type of structured column pacing mode of corrosion-resistant carbon fiber material. These column internals allows for low pressure drop at high throughput rated with reasonable column efficiency. Experiments in columns of 50 and 100 mm diameter have been carried out to investigated separation efficiency, pressure drop and liquid holdup of the packing even at low operation pressures. In the respective columns twp geometrical different types of packing have been tested using binary mixtures of chlorobenzene/ethylbenzene with a packing geometry similar to the Sulzer EX packing, the 100 mm diameter column was filled with elements of rougher structure and smaller specific surface. Basing on the experimental results, model equations are presented, which allow the calculation of the investigated performance characteristics.