ISSN:
0001-1541
Schlagwort(e):
Chemistry
;
Chemical Engineering
Quelle:
Wiley InterScience Backfile Collection 1832-2000
Thema:
Chemie und Pharmazie
,
Werkstoffwissenschaften, Fertigungsverfahren, Fertigung
Notizen:
A method of estimating the true conditions of operation of a bubble-cap tray is presented. Intermediate between the Murphree and the Lewis methods, which represent the extremes of actual operation, this method involves the use of a correlation to determine the degree of liquid mixing on the tray and the use of new relations between the Murphree vapor efficiency, the Lewis case I efficiency, and the true local efficiency. For the last, partial liquid mixing is taken into account.Data were obtained on an 18-in. O.D. three-tray bubble-cap tower containing ten 3-in. bubble caps a tray. Partial liquid mixing was correlated for changes in vapor and liquid rates, pressure, temperature, and weir height for the system ethylene dichloride-toluene.Efficiency data on acetone-water, ethanol-water, and ethylene dichloride-toluene showed the following effects: (1) low concentration of lwo boiler usually, but not always, resulted in low true local efficiencies, always with high Murphree efficiencies; (2) vapor velocity effects are more intimately connected with slot velocity than superficial velocity (and hence entrainment); (3) raising the pressure gives higher efficiencies; (4) an increase in liquid depth increases the true local efficiency but may have no effect on the Murphree efficiency.
Zusätzliches Material:
15 Ill.
Materialart:
Digitale Medien
URL:
http://dx.doi.org/10.1002/aic.690020105