    AIChE Journal 6 (1960), S. 153-156 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: New measurements of the volumes of liquid n-alkanes of 7, 9, 11, 13, 17, 20, 30, and 40 carbon atoms over a range of temperatures from 20° to 300°C. and pressures from 0 to 4,000 kg./sq. cm. have been made. These volume measurements are here reduced to compressions (volpT)/(vol°T), and the accuracy of the measurements has been determined. Analysis of the data for n-heptane and n-eicosane shows that the order of accuracy of the compressions of each of these compounds appears to be approximately 3 parts in 10,000. Evaluation of random multiple measurements on the remaining six compounds indicates that their over-all accuracy is likewise of this same order.