Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Hoboken, NJ : Wiley-Blackwell
    AIChE Journal 24 (1978), S. 473-485 
    ISSN: 0001-1541
    Keywords: Chemistry ; Chemical Engineering
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The use of tracer dispersion measurements in conjunction with associated pressure drop data, as an indirect diagnostic technique for the determination of particle deposit morphology in deep-bed filters, was investigated. The dispersion measurements consisted of the injection of an electrolyte tracer pulse at the inlet and the monitoring of the tracer peak as it traveled down the bed, while the pressure drop data consisted of the axial pressure gradient histories as deposition took place. These data are interpreted using dispersion and pressure drop theories established on the basis of assumed models of deposit morphology. The validity of this technique was confirmed experimentally.
    Additional Material: 14 Ill.