    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 37 (1991), S. 889-893 
    ISSN: 0006-3592
    Keywords: oxygen transfer coefficient ; kLa ; pulsed dynamic method ; mechanically agitated vessels ; Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: This reports on the determination of the overall oxygen transfer coefficient in a mechanically agitated vessel using a randomly pulsed dynamic method. This method consists in exciting the system by randomly switching the inlet gas stream with air or nitrogen with an identical volumetric flow rate. A pseudo-random binary sequence was used. This procedure is routinely used in process control for the identification of system's transfer function. The pulsed dynamic method gives good reliability (as compared with the traditional gassing-out method) and reproducibility in water. However, further improvement is needed before it can be used to monitor on-line the kLa during a fermentation.
    Additional Material: 5 Ill.