Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Applied Organometallic Chemistry 9 (1995), S. 149-158 
    ISSN: 0268-2605
    Keywords: selenium speciation ; high-performance liquid chromatography-atomic absorption spectrometry ; seleno oxyanions ; selenoamino acids ; Chemistry ; Organic Chemistry
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology
    Notes: Several approaches to the determination of selenomethionine, selenocystine, selenite and selenate by high-performance liquid chromatography with online detection by atomic absorption spectrometry are described. The N-2,4-dinitrophenyl derivatives of selenomethionine, selenoethionine, selenocystine and phenylmercury(II) cystineselenoate were recovered from aqueous solution, separated on a Nucleosil 5-NO2 reversed-phase HPLC column with a methanolic mobile phase containing acetic acid and triethylamine, and detected with a quartz thermochemical hydride-generating interface-atomic absorption spectrometry (AA) system. The restriction of having to perform chromatography with an organic mobile phase (to support the combusion process) was overcome with a new interface design capable of operation with either organic or aqueous HPLC mobile phases. Using aqueous acetic acid (0.015% v/v) containing 0.1% (w/v) ammonium acetate delivered at 0.5cm3 min-1, selenate, selenite, selenomethionine, selenocystine and selenoethionine were separated virtually to baseline on a cyanopropyl-bonded phase HPLC column. Other selenium compounds which were investigated included methane seleninic and methane selenonic acids as well as the crude oxidation product mixtures resulting from the treatment of selenomethionine and selenocystine with hydrogen peroxide. A procedure for extracting selenate, selenite, selenomethionine, selenocystine and selenoethionine from spiked water or ground feed supplement into liquefied phenol resulted in acceptable recoveries for the latter four analytes but was unacceptably low for selenate.
    Additional Material: 7 Ill.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...