Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Journal of radioanalytical and nuclear chemistry 226 (1997), S. 41-45 
    ISSN: 1588-2780
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology , Energy, Environment Protection, Nuclear Power Engineering
    Notes: Abstract Secondary ion mass spectrometry (SIMS) is a well-established technique that permits rapid detection of stable and radioactive nuclides. Its resolving mass power provides an efficient analytical method and, in particular, it makes possible accurate isotopic ratio determination. Tests were carried out to evaluate the performance of this technique for the assessment of trace concentrations of uranium and plutonium in urine samples prepared in thin sources. Special attention has been paid to the preparation of the specimens which represents a critical step for the employment of this technique due to the erosion process used by SIMS. Fixation of the matrix in Polypyrrole films have been proved to be suitable. Present results show that concentrations in the order of 10−10 g·1−1 of238U (10−6 Bq·1−1) and 10−11 g·1−1 of239Pu (10−2 Bq·1−1) can be rapidly measured.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗