Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    Graefe's archive for clinical and experimental ophthalmology 186 (1973), S. 191-202 
    ISSN: 1435-702X
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung Eigene Untersuchungen am Menschen hatten früher gezeigt, daß experimentelle Veränderungen der arteriellen Kohlensäurespannung gleichsinnige Änderungen der oculären Tension zur Folge hatten. Der Einfluß des arteriellen Sauerstoffpartialdrucks blieb unklar. Die vorliegende Untersuchung zeigt das Verhalten der oculären Tension und des Rigiditätskoeffizienten bei vergrößertem funktionellem Totraum, also Erhöhung des PaCO2 und Erniedrigung des PaO2. Beim Übergang von Normoventilation auf Versuchsbedingung änderten sich der arterielle Blutdruck von 130/70 auf 145/80, die Pulsfrequenz von 77/min auf 88/min, das AMV von 6,9 l/min auf 26,9 l/min, der PaO2 von 105,7 mmHg auf 74,0 mmHg, der PaCO2 von 34,5 mmHg auf 45,4 mmHg, die oculäre Tension von 7,0 Schiøtz-Einheiten auf 6,0 und der Rigiditätskoeffizient von 0,023 auf 0,015. Dieses Verhalten der verschiedenen Parameter wurde durch einen Selbstversuch unter höherer Belastung bestätigt. Die Untersuchungen zeigen, daß Änderungen des PaCO2 mit gleichsinnigen Änderungen der oculären Tension einhergehen, deren Ausmaß von der Höhe des PaO2 moduliert wird.
    Notes: Summary In former investigations on human eyes the authors had been able to show that experimental changes of the arterial CO2 tension caused similar changes of the ocular tension. The influence of the arterial O2 partial pressure could not be determined. In the present case the reactions of the ocular tension and of the coefficient of rigidity to an experimentally enlarged functional dead — space is investigated, as well as the increase in PaCO2 and the decrease in PaO2. While proceeding from normal ventilation to test conditions the following changes took place: Arterial blood pressure from 130/70 to 145/80, pulse frequence from 77/min to 88/min, TV from 6.9 l/min to 26.9 l/min (TV=tidal volume), PaO2 from 105.7 mmHg to 74.0 mmHg, PaCO2 from 34.5 mmHg to 45.4 mmHg, ocular tension from 7.0 Schiøtz units to 6.0, coefficient of rigidity from 0.023 to 0.015. These reactions of the different parameters could be verified under even stronger conditions with one of the authors as a test person. Investigations showed that changes of the PaCO2 coincide with similar changes of the ocular tension. The extend of these changes is modulated by the degree of the PaO2.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...