    Springer
    Chromatographia 25 (1988), S. 313-318 
    ISSN: 1612-1112
    Keywords: Gas chromatography ; Retention index ; Slope of log plot ; Homologous series ; Partition coefficient
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary The slope of the n-alkane log plot dt′R/dnc (t′R=adjusted retention time; nc=carbon number) for a stationary phase can be used to obtain the retention index of an unidentified substance in a chromatogram containing only one peak with a known retention index, or to predict the retention time of a substance from that of a different homolog in the same series. It can also be used to translate retention indices into relative retention time, partition coefficient or specific retention volume. Published values of the slope are collected and critically evaluated. Equations are deduced that predict its approximate value at a specified temperature given the value at only one other temperature.