    ISSN: 1612-1112
    Keywords: Column liquid chromatography ; Particle beam interface-mass spectrometry ; Water analysis and identification of unknown ; pollutants ; Phenylurea herbicides
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Notes: Summary Trace enrichment on a precolumn packed with copolymer material, coupled on-line with reversed-phase, column liquid chromatography-particle beammass spectrometry (RPLC-PB-MS) has been used for both target and non-target analysis of water samples. RPLC is carried out on a C-18-bonded silica column using a linear acetonitrile-0.1 M ammonium acetate gradient. Using optimised PB-MS conditions and 100–250 ml water samples, the detection limits for several phenylureas are in the 0.03–0.05 μg l−1 range using the full-scan mode; repeatability is good and the LC-PB-MS system is robust. Several surface and drinking water samples have been analysed and low levels of various environmental contaminants have been identified using electron impact mass spectra. Applying chemical ionisation with methane as reagent gas in both the positive and negative mode in conjunction with PB-MS provides relevant confirmatory information.