ISSN:
1612-1112
Keywords:
Gas chromatography
;
Solid phase extraction
;
Polychlorobiphenyls
;
Clorinated pesticides
;
Organochlorine separation
Source:
Springer Online Journal Archives 1860-2000
Topics:
Chemistry and Pharmacology
Notes:
Summary Gas chromatography of polychlorinated biphenyls and chlorinated pesticides in water samples is carried out after adsorption from a 25–500 mL sample, on a cartridge containing 100 mg aminopropyl-bonded porous silica. The clean-up step in which the PCBs and chlorinated pesticides are separated in different eluates is achieved by passing 25 mL of 40% aqueous methanol through the NH2 Sep-Pak cartridge. The PCBs are desorbed with 500 μL ethylacetate, which is concentrated and analysis by GC-ECD. The average recovery, at 1 ppb is 〉97% with a standard deviation 〈2. The limits of detection are 0.1 ng μL−1 and 5 pg μL−1 respectively for Cl3-PCB and Cl8-PCB congeners. In the separation of PCBs from the chlorinated pesticides tested in this work, only the Aldrin is adsorbed for 60% with the PCBs by the NH2 Sep-Pak cartridge. The method described is rapid, simple and reproducible.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/BF02467685