    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 80 (2002), S. 461-463 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: Arrays of nickel posts were used as magnetic elements in a microfiltration device that is compatible with microfluidic systems. The combination of microtransfer molding—a soft lithography technique—and electrodeposition generated nickel posts ∼7 μm in height and ∼15 μm in diameter inside a microfluidic channel. Once magnetized by a magnetic field from an external, permanent, neodymium–iron–boron magnet, these nickel posts generated strong magnetic field gradients and efficiently trapped superparamagnetic beads moving past them in a flowing stream of water. These nickel post arrays were also used to separate magnetic beads from nonmagnetic beads. © 2002 American Institute of Physics.