Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Woodbury, NY : American Institute of Physics (AIP)
    Applied Physics Letters 52 (1988), S. 773-775 
    ISSN: 1077-3118
    Source: AIP Digital Archive
    Topics: Physics
    Notes: The steady-state and dynamic gain characteristics in a KrF amplifier are studied with the use of 1 ps pulses. A saturation energy density in the range 1.8–2.0±0.2 mJ/cm2 is measured. The recovery of the small-signal gain coefficient exhibits two recovery processes with time constants of 67±10 ps and 2.0±0.2 ns.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗