Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    [S.l.] : American Institute of Physics (AIP)
    Review of Scientific Instruments 62 (1991), S. 2523-2534 
    ISSN: 1089-7623
    Source: AIP Digital Archive
    Topics: Physics , Electrical Engineering, Measurement and Control Technology
    Notes: We designed, constructed, and tested at 4.2 K (using two different low phase noise electrical pump generators) a cryogenic double-resonant parabridge motion transducer made out of niobium, whose electrical output was amplified by a two-stage metal-semiconductor field-effect transistor cryogenic amplifier. Most of the experimental results agreed well with the theoretical models. We were able to adjust the two electrical bridge resonant frequencies at the pump frequency, allowing us to obtain an electromechanical coupling as high as 0.054, and we successfully measured the mechanical Brownian motion of this transducer. In one case, we observed a dip in the electrical noise spectrum near the mechanical resonant frequency due to destructive interference between this noise and its "reflection'' from the mechanical resonator. At the bottom of this dip, in a bandwidth of 0.7 Hz, we measured an equivalent displacement noise of 4 × 10−16 m/(square root of)Hz with a systematic error of less than 10%.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...