Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Journal of food science 59 (1994), S. 0 
    ISSN: 1750-3841
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Agriculture, Forestry, Horticulture, Fishery, Domestic Science, Nutrition , Process Engineering, Biotechnology, Nutrition Technology
    Notes: pH measured on a 10% slurry may overestimate values on canned biscuit doughs because of carbon dioxide evolution during slurry preparation. Therefore, a pH method using a surface pH electrode was developed and used to measure pH of biscuits in sealed cans and after opening. pH increased upon opening and continued to increase gradually for 5 min. The slurry method overestimated true dough pH and did not show pH change with time. pH of yeast-leavened bread dough measured by the slurry method was also higher than that by the surface method. The surface pH electrode is a reliable, accurate method of pH determination in leavened doughs.