Library

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Ground water 42 (2004), S. 0 
    ISSN: 1745-6584
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Energy, Environment Protection, Nuclear Power Engineering , Geosciences
    Notes: We constructed a numerical model of transient ground water flow and solute transport for a portion of the Biscayne Aquifer in Florida, and calibrated the model with three different combinations of data from a 193-day period: head (h) data alone, data on h and ground water discharge to a canal (q), and data on h, q, and ground water chloride concentration (C). We used each of the three calibrated models to predict h and q during a 182-day test period separate from the calibration period. All three calibrated models predicted h equally well during the test period (r= 0.95, where r= 1 indicates perfect agreement between measured and simulated values), though the model calibrated on h alone had significantly different parameter values than the other two models. Predictions of q during the test period depended on calibration methodology; models calibrated with multiple targets simulated q more accurately than the model calibrated on h alone (r = 0.79 compared to r = 0.49). Based on the results of these simulations, we conclude: (1) Post-calibration prediction is important in assessing the value of different data types in automated calibration; (2) inverse-solution uniqueness is not a requirement for accurate h predictions; (3) relatively simple models can predict with reasonable accuracy transient ground water flow in a complex aquifer, and parameters governing this prediction can be estimated by nonlinear regression methods that incorporate both h and q data; (4) addition of C data to the calibration did not improve model predictive capacity because the information in the C data was similar to that in the q data, from the perspective of model calibration (the subsurface chemical signal in question was controlled mainly by seepage of high-chloride canal water into the low-chloride ground water system).
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...