    Keywords: Magnetic resonance imaging ; Nuclear magnetic resonance ; Central nervous system
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Notes: Abstract This study was set up to see whether lowering the flip angle in proton density- and T2-weighted double-spin echo sequences allows for shortening of repetition time (TR) and imaging time without significant change of image quality. Ten patients with celebral white matter lesions were investigated with an 1.5 T MR scanner using a conventional long- TR double-spin echo sequence (TR = 2500 ms, TE = 15 and 70 ms) and reduced-TR double-spin echo sequences (TR = 1900 ms, TE = 15 and 70 ms) at flip angles of 90°, 80°, 70°, 60°, and 50°. Lowering the flip angle resulted in less T1-contrast and a relative increase of T2-contrast. At a flip angle of 70°, contrast-to noise ratios (NNRs) between lesions and brain, as well as image artifacts of the reduced-TR sequence (CNR: 22.4) were similar to the conventional long-TR sequence (CNR:21.1), while imaging time was shortened by about 25%.