ISSN:
1433-0350
Keywords:
Key words Hydrocephalus model
;
Kaolin
;
Micro-balloon
;
Rat
Source:
Springer Online Journal Archives 1860-2000
Topics:
Medicine
Notes:
Abstract We used three types of specialized micro-balloons 0.7–1.35 mm in outer diameter instead of kaolin to develop a reproducible rat model of hydrocephalus with a low experimental mortality. The micro-balloon was inserted 6 mm deep into the cisterna magna via a burr hole immediately behind the lambda. The angle of introduction was 50°. We also set up kaolin-induced hydrocephalic models in 25 rats as controls. The kaolin model revealed 52% mortality with an 80% induction rate of hydrocephalus, while the balloon model showed 9% mortality with a 60% induction rate. Balloon-induced hydrocephalus was maximal at 1 week and tended to decrease after 2–3 weeks. The pathological findings were not different between the two models. We concluded that the micro-balloon model for hydrocephalus is an easily reproducible model with low experimental mortality.
Type of Medium:
Electronic Resource
URL:
http://dx.doi.org/10.1007/s003810050385