Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (2)
  • 1995-1999  (2)
  • 1998  (2)
  • 1
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Transcatheter radiofrequency (RF) ablation of atrial fibrillation or flutter requires the creation of linear lesions. However, conventional catheters are not predictably effective because of poor endocardial contact, and limited lesion size and penetration. The purpose of the study was to assess, in the right atrium, the efficacy and safety of a new catheter designed to create long myocardial tissue lesions using RF energy. The main characteristics of this 8 Fr deflectable RF ablation catheter were: (1) a perpendicularly contacting articulated bilimb electrodes ensuring stable and firm endocardial firm contact; and (2) an irrigated planar interface. Three different electrode prototypes were tested. Fourteen anesthetized sheep weighing 61 ± 7 kg underwent RF ablation in the right atrium using three incremental power levels (25 to 45, 50, 55 to 75 W) with the aim of creating fully transmural (FT) lesions, defined as continuous and complete epicardial and endocardial lesion imprints. The animals were euthanized 1 hour later for macroscopic and histologic examinations. Forty-three of the 80 right atrial lesions created, in smooth as well as in trabeculated areas, were FT. The percentage of FT lesions increased with the applied power from 37% with 25–45 W, to 49% with 50 W, and up to 86% for 55–75 W. In all but two cases, histologic examination showed no discontinuity between FT lesions produced by both limbs resulting in 19 coalescent linear lesions with an average size of 25 × 6 × 4 mm (length × width × depth). In situ bipolar electrograms after ablation in the FT group showed split potentials and/or a marked decrease in amplitude from 2.85 ± 1.79 to 0.33 ± 0.14 mV (P = 0.001) accompanied by near complete disappearance of unipolar electrograms. There was no perforation due to RF ablation. In conclusion, continuous and FT lesions can be achieved in various areas of sheep atria, including the trabecular right atrium, with a perpendicularly contacting bilimb electrode catheter. It represents a promising tool for catheter ablation of atrial fibrillation and flutter.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    The European physical journal 5 (1998), S. 413-417 
    ISSN: 1434-6036
    Keywords: PACS. 71.27.+a Strongly correlated electron systems; heavy fermions - 71.30.+h Metal insulator transitions and other electronic transitions - 78.20.-e Optical properties of bulk materials and thin films
    Source: Springer Online Journal Archives 1860-2000
    Topics: Physics
    Notes: Abstract: The optical absorption in ferromagnetic metal La1-xSrxMnO3 is anomalous; it has a wide-range absorption up to about 1 eV even at zero temperature. Since 3d electrons in La1-xSrxMnO3 partially fill doubly degenerate eg orbitals, the orbital degrees of freedom are crucial to understand this metallic system. We argue that the interband transition within eg orbitals is important in the optical absorption. The optical spectrum is modified also by the inter-orbital Coulomb interaction. We have examined perturbatively the effect of the Coulomb interaction on the spectrum. Available experiments are discussed by comparing with the present results.
    Type of Medium: Electronic Resource
    Library Location Call Number Volume/Issue/Year Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...