Library

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Articles: DFG German National Licenses  (1)
  • 1970-1974  (1)
Source
  • Articles: DFG German National Licenses  (1)
Material
Years
Year
  • 1
    Electronic Resource
    Electronic Resource
    Springer
    European journal of pediatrics 108 (1970), S. 221-230 
    ISSN: 1432-1076
    Keywords: Congenital Heart Diseases ; Flow-guided Catheterization ; Micro-heartcatheterization ; Heart-diagnostic
    Source: Springer Online Journal Archives 1860-2000
    Topics: Medicine
    Description / Table of Contents: Zusammenfassung 1. Es wird die Methode zur Mikrokatheterisierung des rechten Herzens und der Pulmonalarterie ohne Röntgenkontrolle nach Grandjean beschrieben. 2. Voruntersuchungen galten der Feststellung der Fehlerbreite der Methode und der Erkennung von technischen Schwierigkeiten besonders im Kindesalter. 3. Beispiele zeigen die praktische Anwendung der Methode im Kindesalter. 4. Die Grenzen der Methode — vor allem Schwierigkeiten bei der Einführung des Mikrokatheters — sowie Komplikationen und Gefahren der Mikro-HK werden angegeben. Extrasystolen, z. T. salvenförmig, sind regelmäßig zu beobachten, auch gefährlichere Herzrhythmusstörungen können auftreten. Dreimal kam es zu Schlingen-und Knotenbildung des Mikrokatheters. 5. Die bisher erarbeiteten Indikationen und Kontraindikationen der Mikro-HK im Kindesalter werden formuliert. Die Methode eignet sich nicht zur präoperativen Diagnostik von Angiokardiopathien. Sie kann die übliche Herzkatheterisierung ergänzen; sie ist ausgezeichnet geeignet für Verlaufskontrollen und Nachuntersuchungen prä- und postoperativer Fälle. Den größten Vorteil stellt die ambulante Durchführbarkeit der Untersuchung dar.
    Notes: Abstract 1. A description of the technique of the self-guiding catheter (miniature catheter) of the right heart and the pulmonary artery without X-ray visualisation according to Grandjean is presented. 2. Preliminary tests were carried out to estimate the range of error of the method, and to determine technical difficulties, particularly those that arise in infants and children. 3. Examples are given which demonstrate the practical application of the technique in infants and children. 4. The limitations of the method, especially the difficulties that risea in introducing the self-guiding catheter, as well as the complications and dangers of the self-guiding catheterization technique of the heart are mentioned. Extrasystoles which sometimes occur in rapid succestion were regularly encountered, as well as even more dangerous disturbances of the cardiac rate. In three cases a loop and knot formation of the miniature catheter was observed. 5. Indications and contraindications of the self-guiding cardiac catheterization technique are discussed. The method is not suitable for the pretive diagnosis-opera of angiocardiopathies. It can supplement the usual cardiac catheterization; it is excellently suitable for controlling the course, and checking up pre- and post-operative cases. The greatest advantage of the method is that it can be used in out-patients.